108
•
Openings & Closings
- Sets Residential Dial Reporting Codes for all openings and closings
•
Zone Alarm Restore Group -
Disables all zone alarm restore reporting codes
•
Installer Lead-in/Lead-out and DLS Lead-in/Lead-out
•
Digit 5 DLS Connection Options
After entering a valid 5-digit template programming code, the system prompts for the following data in the sequence listed:
1.
Central Station Telephone Number
Program the required central station phone number. Press [#] to complete your entry.
This phone number is entered into programming section [301][001].
2.
Central Station Account Code (6-digit code)
Program the system account code. All 6 digits must be entered in order to complete your entry.
This account code is entered into programming section [310][000].
3.
DLS Access Code (6-digit code)
Openings/Closings Group
Openings/Closings Programming
Enable All User Open/Close Reports
[308][201] - Bit 1 User Closing - On
[308][201] - Bit 2 User Opening - On
[308][201] - Bit 3 Partition Closing - Off
[308][201] - Bit 4 Partition Opening - Off
[308][201] - Bit 5 Special Closing - On
[308][201] - Bit 6 Special Opening - On
[308][202] - Bit 1 Automatic Closing - On
[308][202] - Bit 3 Automatic Cancel - On
Zone Alarm Restore Group
DLS/Installer Lead In/Out Programming
Restore zone alarm reporting codes
[307][001] - Bit 2 Alarm Restore - Off
[307][002] - Bit 2 Alarm Restore - Off
[307][003] - Bit 2 Alarm Restore - Off
[307][004] - Bit 2 Alarm Restore - Off
[307][005] - Bit 2 Alarm Restore - Off
[307][006] - Bit 2 Alarm Restore - Off
[307][007] - Bit 2 Alarm Restore - Off
[307][008] - Bit 2 Alarm Restore - Off
[307][009] - [128] Bit 2 Alarm Restore - Off
DLS/Installer Lead In/Out Group
DLS/Installer Lead In/Out Programming
DLS/Installer Disabled
[308][312] - Bit 1 Installer Lead In - Off
[308][312] - Bit 2 Installer Lead Out - Off
[308][312] - Bit 3 DLS Lead In - Off
[308][312] - Bit 4 DLS Lead Out - Off
[308][312] - Bit 5 SA Lead In - Off
[308][312] - Bit 6 SA Lead Out - Off
Option
Programming Section
DLS Connection/Call Back Setting
1
[401] Option 1 OFF
Option 3 OFF
Option 4 OFF
[406] 000
Double Call Disabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On Disabled
2
[401] Option 1 ON
Option 3 OFF
Option 4 OFF
[406] 008
Double Call Enabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
3
[401] Option 1 ON
Option 3 ON
Option 4 OFF
[406] 008
Double Call Enabled
Call Back Enabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
4
[401] Option 1 ON
Option 3 OFF
Option 4 ON
[406] 008
Double Call Enabled
Call Back Disabled
User Initiated Call Up Enabled
Number of Rings to Answer On is 8