S e c t i o n 4 : S y s t e m O p e r a t i o n
23
4.9 Visual Verification
This feature enables the central station operator to view captured
images of the premises in the event of an alarm event. Combination
camera/motion detectors can be installed throughout the premises to
provide visual verification coverage. The microphone on the camera
PIR can be disabled.
Visual verification sessions are triggered by the following:
•
Fire key
•
Medical key
•
Panic key
To set up video verification on a partition:
•
Enroll the camera PIR; [804]
•
Set video verification options; [804]>[841]:
• [001] Visual Verification Enable/Disable
• [002] View Time Window
• [003] View Other Alarms
•
Input a custom label to identify the camera PIR; [000]>[001]
•
Enable this option on the alternate communicator (section [10]
option 2).
Refer to the Camera PIR installation manual for more details.
NOTE:
Visual Verification has not been evaluated by UL and shall be
disabled for UL certified installations.
firealarmresources.com