ConnectMe Tunstall Vi+ Installation and Programming Manual
37
Intruder monitoring
The home unit has the ability to provide a simple to use intruder alarm facility, which
will alert the monitoring centre or personal recipient on detection of an intruder.
When configured using the series telephone keypad, the intruder monitoring function
is simplified and uses a number of default settings. These settings other than the
entry/exit times period, can only be configured using the PC Connect programming
tool or via the monitoring centre.
By turning the function ON using the keypad, Intruder monitoring will use the
following settings.
Arm method
– press the away button, unit announces ‘Away’ and entry/exit
tones will be heard for 30 seconds.
Disarm method
– press away button followed by the personal radio trigger,
the unit will announce ‘Home’ and the entry/exit tones will stop.
To configure the intruder settings use the following quick codes:
61xx
Enable intruder and set entry/exit tones
Where xx is in seconds
6413
Enable intruder disarm method of AWAY and personal
trigger
6403
Disable intruder disarm method of AWAY and personal
trigger
6414
Enable intruder disarm method by PIN
6404
Disable intruder disarm method by PIN
6415
Enable intruder disarm method by arm/disarm trigger
6405
Disable intruder disarm method by arm/disarm trigger
If an intruder detection event is detected that is within the armed zone(s) and is from
an entry/exit sensor then the entry period will commence and entry tones will sound.
The user has until the entry period expires to disarm the intruder system otherwise
an intruder alarm will be generated.
NOTE
:
The intruder function can be configured to meet the individual user’s need using either the PC
Connect programming tool or via the monitoring centre. This enables more complex settings to be
configured including: different arming methods, optional entry/exit tones, how the unit reacts to intruder
detection events (event-based configuration), zoning etc.
Event configuration
This feature enables the home unit to react to each event in a different way and
allows these events to be configured via PC Connect and PNC (non telecare sensor
events only) based on whether they should; raise an alarm call, act as an
intruder/inactivity system input, provide visual/audible reassurance, enable the
microphone/speaker, operate the relay output plus much more. The events are split
into the following categories:
Buttons
Virtual sensors (Tunstall Vi+ only)
Faults
Telephony
Misc.