ConnectMe Tunstall Vi+ Installation and Programming Manual
57
AD
TES Fault
032
High Temperature
06
Fault status (alarm not active)
Ad
TES Fault (LB)
032
High Temperature
06
Fault status (alarm not active)
AE
TES Low Temp
033
Low Temperature
00
Normal default
Ae
TES Low Temp (LB)
033
Low Temperature
07
Low battery status set
AF
TES Temp Rise
034
Temperature rate of
rise
00
Normal default
Af
TES Temp Rise (LB)
034
Temperature rate of
rise
07
Low battery status set
AG
TES AP
032
High Temperature
08
Busy
Ag
TES AP (LB)
032
High Temperature
08
Busy
A2
TES ALB
032
High Temperature
06
Fault status (alarm not active)
A3
TES AP Fail
032
High Temperature
06
Fault status (alarm not active)
AG
TES AP Restore
032
High Temperature
04
In service (fault rectified)
AH
Flood Detector activation
047
Flood
00
Normal default
Ah
Flood Detector activation (LB)
047
Flood
07
Low battery status set
AI
Flood Detector AP
047
Flood
08
Busy
Ai
Flood Detector AP (LB)
047
Flood
08
Busy
A4
Flood Detector ALB
047
Flood
06
Fault status (alarm not active)
A5
Flood Detector AP Fail
047
Flood
06
Fault status (alarm not active)
AI
Flood Detector AP Restore
047
Flood
04
In service (fault rectified)
AJ
CO Detector activation
026
Carbon Monoxide
00
Normal default
Aj
CO Detector activation (LB)
026
Carbon Monoxide
07
Low battery status set
AK
CO Detector EOL
026
Carbon Monoxide
09
Out of Service
Ak
CO Detector EOL (LB)
026
Carbon Monoxide
09
Out of Service
AL
CO Detector fault
026
Carbon Monoxide
06
Fault status (alarm not active)
Al
CO Detector fault (LB)
026
Carbon Monoxide
06
Fault status (alarm not active)
AM
CO Detector AP
026
Carbon Monoxide
08
Busy
Am
CO Detector AP (LB)
026
Carbon Monoxide
08
Busy
A6
CO Detector ALB
026
Carbon Monoxide
06
Fault status (alarm not active)
A7
CO Detector AP Fail
026
Carbon Monoxide
06
Fault status (alarm not active)
AM
CO Detector AP Restore
026
Carbon Monoxide
04
In service (fault rectified)
AN
Smoke Detector activation
016
Smoke
00
Normal default
An
Smoke Detector activation (LB)
016
Smoke
07
Low battery status set
AO
Smoke Detector AP
016
Smoke
08
Busy
Ao
Smoke Detector AP (LB)
016
Smoke
08
Busy
A8
Smoke Detector ALB
016
Smoke
06
Fault status (alarm not active)
A9
Smoke Detector AP Fail
016
Smoke
06
Fault status (alarm not active)
AO
Smoke Detector AP Restore
016
Smoke
04
In service (fault rectified)
AQ
Door Usage opening
013
Door Contact
00
Normal default
Aq
Door Usage opening (LB)
013
Door Contact
07
Low battery status set
AR
Door Usage closing
013
Door Contact
00
Normal default
Ar
Door Usage closing (LB)
013
Door Contact
07
Low battery status set
AS
Door Usage AP
013
Door Contact
08
Busy
As
Door Usage AP (LB)
013
Door Contact
08
Busy
B0
Door Usage ALB
013
Door Contact
06
Fault status (alarm not active)
B1
Door Usage AP Fail
013
Door Contact
06
Fault status (alarm not active)
AS
Door Usage AP Restore
013
Door Contact
04
In service (fault rectified)
AT
Pressure Mat activation
012
Pressure Mat
00
Normal default
At
Pressure Mat activation (LB)
012
Pressure Mat
07
Low battery status set
AU
Pressure Mat AP
012
Pressure Mat
08
Busy
Au
Pressure Mat AP (LB)
012
Pressure Mat
08
Busy
B2
Pressure Mat ALB
012
Pressure Mat
06
Fault status (alarm not active)
B3
Pressure Mat AP Fail
012
Pressure Mat
06
Fault status (alarm not active)
AU
Pressure Mat AP Restore
012
Pressure Mat
04
In service (fault rectified)
AV
Pullcord activation
011
Fixed trigger 2
00
Normal default
Av
Pullcord activation (LB)
011
Fixed trigger 2
07
Low battery status set
AW
Pullcord AP
011
Fixed trigger 2
08
Busy
Aw
Pullcord AP (LB)
011
Fixed trigger 2
08
Busy
B4
Pullcord ALB
011
Fixed trigger 2
06
Fault status (alarm not active)
B5
Pullcord AP Fail
011
Fixed trigger 2
06
Fault status (alarm not active)
AW
Pullcord AP Restore
011
Fixed trigger 2
04
In service (fault rectified)
AX
Enuresis Sensor activation
036
Enuresis
00
Normal default
Ax
Enuresis Sensor activation (LB)
036
Enuresis
07
Low battery status set
AY
Enuresis Sensor AP
036
Enuresis
08
Busy
Ay
Enuresis Sensor AP (LB)
036
Enuresis
08
Busy
B6
Enuresis Sensor ALB
036
Enuresis
06
Fault status (alarm not active)
B7
Enuresis Sensor AP Fail
036
Enuresis
06
Fault status (alarm not active)
AY
Enuresis Sensor AP Restore
036
Enuresis
04
In service (fault rectified)
AZ
Bed/Chair Not in
037
Bed Occupancy
00
Normal default
Az
Bed/Chair Not in (LB)
037
Bed Occupancy
07
Low battery status set
BA
Bed/Chair Not up
037
Bed Occupancy
00
Normal default
Ba
Bed/Chair Not up (LB)
037
Bed Occupancy
07
Low battery status set