Hardwired input
The hardwired input is located on the underside of the unit with a green 2 wire sprung
terminal block. Inputs can be normally open or normally closed volts free contacts.
To set an input you will need to configure the unit accordingly either with the serial
telephone Quick Codes below, a PNC5/6 monitoring centre or via PC Connect.
45xx
Set hardwire input to trigger type number
Where xx trigger type code, see table 3
46xy
Set hardwired input sensor
x = 0 for disable, 1 = n/o, 2 = n/c
y = 1 for zone 1 and 2 = zone 2
47xx
Set hardwired input location
Where xx is TT21 location code, see
table 2
Hardwired output
The hardwired output in the Tunstall Vi+ home unit provides common (COM),
normally closed (NC) and normally open (NO) contacts.
Its operation can be controlled via a series telephone using the quick codes below, or
by setting the correct boxes in the Remote Output Control of PC Connect or remotely
by a PNC5/6 monitoring centre.
3011
Activate external relay for 2 seconds
All alarms (Call Raised)
3012
Activate external relay for all alarms when call
selected and de-activate when calls cleared
Call Selected
Call Cleared
3013
Activate external relay on radio smoke alarm and
de-activate when cleared
Smoke Alarm
Call Cleared
3014
Disable external relay for all events