background image

ConnectMe Tunstall Vi+ Installation and Programming Manual   

 61 

Bq 

Keypad Event 4 Activation (LB) 

010 

Fixed trigger 1 

07 

Low battery status set 

DO 

Keypad AP 

010 

Fixed trigger 1 

08 

Busy 

Do 

Keypad AP (LB) 

010 

Fixed trigger 1 

08 

Busy 

F4 

Keypad ALB 

010 

Fixed trigger 1 

06 

Fault status (alarm not active) 

F5 

Keypad AP Fail 

010 

Fixed trigger 1 

06 

Fault status (alarm not active) 

DO 

Keypad AP Restore 

010 

Fixed trigger 1 

04 

In service (fault rectified) 

HA 

Red Button 

010 

Fixed trigger 1 

00 

Normal default 

Ha 

Cancel Button 

010 

Fixed trigger 1 

00 

Normal default 

HB 

DE Privacy Button 

010 

Fixed trigger 1 

00 

Normal default 

Hb 

Talk Button 

010 

Fixed trigger 1 

00 

Normal default 

HC 

Door Open Button 

010 

Fixed trigger 1 

00 

Normal default 

Hc 

Away Button 

010 

Fixed trigger 1 

00 

Normal default 

HD 

Function Button #4 

010 

Fixed trigger 1 

00 

Normal default 

IA 

Intruder Alarm 

028 

Intruder 

00 

Normal default 

Ia 

Inactivity Alarm 

043 

Inactivity 

00 

Normal default 

IB 

Periodic Call 

058 

Automatic periodic test 
call 

00 

Normal default 

Ib 

Firemans Switch 

010 

Fixed trigger 1 

00 

Normal default 

IC 

Fire Panel Input 

017 

Fire 

00 

Normal default 

Ic 

Medical Reminder - No Ack 

035 

Medication dispenser 

00 

Normal default 

ID 

ADLife - Data 

057 

System status 

00 

Normal default 

Id 

Virtual Bed/Chair #1 Absence 

037 

Bed Occupancy 

00 

Normal default 

IE 

Virtual Bed/Chair #1 Client In 

037 

Bed Occupancy 

00 

Normal default 

Ie 

Virtual Bed/Chair #1 Client Out 

037 

Bed Occupancy 

00 

Normal default 

IF 

Virtual Bed/Chair #2 Absence 

037 

Bed Occupancy 

00 

Normal default 

If 

Virtual Bed/Chair #2 Client In 

037 

Bed Occupancy 

00 

Normal default 

IG 

Virtual Bed/Chair #2 Client Out 

037 

Bed Occupancy 

00 

Normal default 

Ig 

Virtual Inactive Client #1  

043 

Inactivity 

00 

Normal default 

IH 

Virtual Inactive Client #2 

043 

Inactivity 

00 

Normal default 

Ih 

Virtual Inactive Client #3 

043 

Inactivity 

00 

Normal default 

II 

Virtual Inactive Client #4 

043 

Inactivity 

00 

Normal default 

Ii 

Virtual PES  

030 

Property Exit 1 

00 

Normal default 

IJ 

H/W Input #1 

010 

Fixed trigger 1 

00 

Normal default 

Ij 

H/W Input #2 

010 

Fixed trigger 1 

00 

Normal default 

IK 

SM Low Temp Input (Code 6) 

010 

Fixed trigger 1 

00 

Normal default 

Ik 

SM Auxiliary Input (Code 0) 

010 

Fixed trigger 1 

00 

Normal default 

IL 

Warden Panic Alarm 

023 

Personal attack 1 

00 

Normal default 

Il 

Carer Arrived 

091 

Service call 

00 

Normal default 

IM 

Carer Non-Arrival 

091 

Service call 

09 

Out of Service 

Im 

SM Smoke Input (Code 3) 

016 

Smoke 

00 

Normal default 

IN 

SM CMPS Input (Code 2) 

011 

Fixed trigger 2 

00 

Normal default 

In 

SM Inactivity Input (Code 7) 

043 

Inactivity 

00 

Normal default 

JA 

Mains Fail 

051 

Mains power 

06 

Fault status (alarm not active) 

Ja 

Mains Restore 

051 

Mains power 

04 

In service (fault rectified) 

JB 

System Battery Low 

053 

Battery 

00 

Normal default 

Jb 

Auto Presence Failure 

057 

System status 

06 

Fault status (alarm not active) 

JC 

Auto Low Battery 

057 

System status 

06 

Fault status (alarm not active) 

Jc 

Telephone Line #1 Fail 

059 

Telephone line 1 

06 

Fault status (alarm not active) 

JD 

Telephone Line #1 Restore 

059 

Telephone line 1 

04 

In service (fault rectified) 

Jd 

Telephone Line #2 Fail 

060 

Telephone line 2 

06 

Fault status (alarm not active) 

JE 

Telephone Line #2 Restore 

060 

Telephone line 2 

04 

In service (fault rectified) 

Je 

Pager Fault 

063 

Serial Data Link 

06 

Fault status (alarm not active) 

JF 

CCFP Paging Fault 

063 

Serial Data Link 

06 

Fault status (alarm not active) 

Jf 

Fault - Radio System 

061 

Radio receiver 

06 

Fault status (alarm not active) 

JG 

Fault - Poll Failure 

057 

System status 

06 

Fault status (alarm not active) 

Jg 

Fault - Door Panel Keypad 

057 

System status 

06 

Fault status (alarm not active) 

JH 

Fault - Failed To Contact ARC 

057 

System status 

06 

Fault status (alarm not active) 

Jh 

Fault - SAG Failure 

057 

System status 

06 

Fault status (alarm not active) 

JI 

AP Restore 

057 

System status 

04 

in service (fault rectified) 

J1 

EEPROM Fail 

057 

System status 

06 

Fault status (alarm not active) 

J2 

Stuck Key 

057 

System status 

06 

Fault status (alarm not active) 

J3 

Fault #3 

057 

System status 

06 

Fault status (alarm not active) 

J4 

Fault #4 

057 

System status 

06 

Fault status (alarm not active) 

J5 

Fault #5 

057 

System status 

06 

Fault status (alarm not active) 

J6 

Fault #6 

057 

System status 

06 

Fault status (alarm not active) 

J7 

Manual Test Alarm 

010 

Fixed trigger 1 

00 

Normal default 

J8 

Fault - Unit Failure 

057 

System status 

06 

Fault status (alarm not active) 

J9 

Battery Charged 

053 

Battery 

04 

Normal default 

J0 

Fault #10 

057 

System status 

06 

Fault status (alarm not active) 

KA 

Door Call 

057 

System status 

00 

Normal default 

Ka 

Ringing start 

057 

System status 

00 

Normal default 

Содержание ConnectMe Vi+

Страница 1: ...ConnectMe Tunstall Vi Installation and Programming Guide...

Страница 2: ...15 Maintenance 15 Programming guide 15 How to program via PC Connect programming software 18 How to program via PNC software 18 PNC6 18 PNC5 18 PNC3 4 18 How to program using a series telephone 18 Ho...

Страница 3: ...1 Pendant test reminders 43 Ambient Temperature Sensor 44 Radio interference monitor 45 Voice announcer function 46 Alarm control by time 47 Times when voice announcer messages are played Tunstall Vi...

Страница 4: ...nit Personal radio trigger Amie Personal radio trigger wearing options Neckcord Wrist strap Belt Clip Installation and User Guide Leads and adaptors Australia New Zealand Telephone lead 3 metre cable...

Страница 5: ...ConnectMe Tunstall Vi Installation and Programming Manual 5 Your home unit DC Top View Bottom View Rear View...

Страница 6: ...ernatively a Safe Socket part number TSSAUS01 can be installed on all extensions used by other equipment except the Tunstall to ensure that alarm calls are raised even when the line is being used by a...

Страница 7: ...ome unit socket labelled LINE and the telephone wall socket Step B Plug the telephone adaptor into the home unit socket labelled and then plug all required telephones equipment into the telephone adap...

Страница 8: ...that are programmed to the unit e g Smoke detector Step 3 Adding personal triggers telecare sensors For more information on adding personal triggers please see page 16 of this guide The programming se...

Страница 9: ...e stand and wall bracket are available for the Tunstall Vi see part numbers below Fitting the Table Stand D5102132 This allows the buttons and speaker to be angled towards the user This also covers wh...

Страница 10: ...stallation and Programming Manual 10 Fitting the wall bracket D5102130 The Tunstall Vi can be wall mounted using the optional bracket this conceals the cables where they connect to the unit X 2 2a 3a...

Страница 11: ...an alarm call Alarm calls made from a personal radio trigger can be cancelled immediately by pressing the green cancel button Answering calls remotely via the personal trigger Personal radio triggers...

Страница 12: ...should contact your telephone line supplier e g Testra Optus Vodaphone etc as the telephone line may be faulty Power failure monitoring If a power failure occurs the home unit will continue to work u...

Страница 13: ...ng 1every 4 seconds Low Internal Battery Red LED flashing 1 every second Telephone line disconnected Red Green flashing Radio Blocking Detected No lights on Unit powered down if power is on and connec...

Страница 14: ...le please contact your supplier NOTE Whilst in Step 3 the following quick codes can be entered via the series telephone handset to configure telecare sensors related to the intruder setup 6003 Set las...

Страница 15: ...afterwards to avoid any damage to the speaker NOTE Do not touch the speaker when the speaker cover has been removed Maintenance The unit contains no user serviceable parts The Tunstall home unit batte...

Страница 16: ...es at a glance section Icon Feature PC Connect 1 40 or above PNC4 V2 5 1 PNC5 6 Series Telephone Installer Keypad Telephone Numbers IDs Full Full Full Basic keypad codes Basic keypad codes Inactivity...

Страница 17: ...ch Configuration Full Manual Entry Manual Entry None None Output Configuration Full Full Full None None Virtual Sensors Full Settings adjustable initial setup via PC Connect Settings adjustable initia...

Страница 18: ...ns to program the features of the home unit remotely PNC5 From PNC5 the programming screens will be the same as Tunstall Connect and Connect home units Therefore some new features will not have progra...

Страница 19: ...24 hour clock in the home unit which automatically adjusts to AEST During power cuts the clock is backed up by the home unit s battery for up to 40 hours However if the unit is powered down for transi...

Страница 20: ...er 4 replace 00 with 08 To set tel number 9 replace 00 with 41 To set tel number 5 replace 00 with 09 To set tel number 10 replace 00 with 42 To set tel number 6 replace 00 with 10 NOTE A pause can be...

Страница 21: ...e home unit by pressing Unit ID max 12 digits Sets Unit ID 1 To set Unit ID 2 replace 02 with 12 To set Unit ID 7 replace 02 with 17 To set Unit ID 3 replace 02 with 13 To set Unit ID 8 replace 02 wit...

Страница 22: ...in preference to DTMF for all future alarm calls Using the following quick codes Tunstall Vi home units can easily be set to use DTMF or STMF or automatically choose NOTE Before using STMF the PNC mon...

Страница 23: ...home unit to have No inactivity monitoring no line fail warnings audio or visual but with mains audio fail warning on press 12HRS 24HRS 65 64 61 60 25 24 21 20 75 74 71 70 35 34 31 30 45 44 41 40 05 0...

Страница 24: ...ne before exiting program mode where z 0 for zone 1 and 1 for zone 2 xx TT21 location code see table 1 45xx Set hardwire input to trigger type number Where xx trigger type code see table 2 46xy Set ha...

Страница 25: ...ce Monitor Visual alerts persist only 7XYY Virtual Bed chair Absence time period Valid values of X are 1 and 2 for Virtual Bed Chair sensors 1 and 2 respectively Valid values of YY are 00 to 59 minute...

Страница 26: ...ID card or this quick reference card Connecting the Keypad Programming Any parameter value can be set by using the keypad to program a parameter enter the following key sequence AAA BBBB max 16 digits...

Страница 27: ...at require the time date to be correct E G virtual property exit sensor To set the time on the keypad enter HHMM 24hr format To set the date on the keypad enter DDMMYYYY To check the time and date the...

Страница 28: ...ent alarm numbers press Pauses and dialing method Pauses can be inserted before alarm numbers or where a prefix is used between the prefix and the alarm number The length of the pause and the dialing...

Страница 29: ...s alarm number 1 twice and thereafter calls alarm numbers 2 3 and 4 once each If there is no answer from any of the four numbers the Vi calls alarm number 1 again but this time four times and then cal...

Страница 30: ...D is linked to an alarm receiver the first valid code will be used The actual number of digits sent to the alarm receiver depends upon the type of monitoring centre being used Please contact your moni...

Страница 31: ...al a beep to monitoring centre if they cannot speak 180 Inactivity monitoring Continuous Mode 3 with elapsed time of 16 hrs 181 Intruder monitoring Entry exit period 30 sec 190 Power failure alarm Sen...

Страница 32: ...alarm call will be raised following a 5 minute warning period NOTE Mode 1 generates an alarm if the user is inactive for a configurable 12 or 24 hour period continuous period Mode 2 generates an alar...

Страница 33: ...to a reminder message When a message is due to be played the Tunstall home unit will bleep and announce Reminder every 30 seconds The user must press the cancel button to hear the message If the user...

Страница 34: ...ed template should only be applied to home units of the same model and release level as the unit from which it was read otherwise a warning will be given and the process halted Save a template into th...

Страница 35: ...The away button can be set to provide different actions when pressed these include Standard Home Away the Away button will suspend inactivity monitoring and arm the intruder alarm if it is enabled Se...

Страница 36: ...re alerts are received close to the System Battery Low and Battery or Unit Failure messages then it can be assumed that the message relates to the battery backup time remaining during a power failure...

Страница 37: ...intruder disarm method by PIN 6404 Disable intruder disarm method by PIN 6415 Enable intruder disarm method by arm disarm trigger 6405 Disable intruder disarm method by arm disarm trigger If an intru...

Страница 38: ...1 and 2 zone 2 47xx Set hardwired input location Where xx is TT21 location code see table 2 Hardwired output The hardwired output in the Tunstall Vi home unit provides common COM normally closed NC an...

Страница 39: ...4pm 7pm In all modes before an inactivity alarm is raised an inactivity warning period will occur This is fixed at 10 minutes for Mode 1 and is configurable between 0 and 9 minutes for Modes 2 and 3 T...

Страница 40: ...nal recipient messages Tunstall Vi only A personal recipient message can be recorded on the Tunstall Vi home unit to replace the ID message that a personal recipient would normally hear when they rece...

Страница 41: ...e Identification CLI and automatically divert the caller to the IVR reminder menu NOTE The home unit s clock must be set to operate reminder functionality IVR reminder menu Step 1 Use a normal telepho...

Страница 42: ...press the following on the connected telephone keypad Then record the message Press to end the recording Note 1 6 represents the message slot number If a message is already recorded under the number...

Страница 43: ...he user again at a different time the following day If the resident raises the test call via their alarm button personal trigger when prompted this will be followed by a 2nd message Press the green ca...

Страница 44: ...ht time suppression check box stops alarms been raised during night time hours These are set under the Time Window function The status section shows the last measured temperature this will be the temp...

Страница 45: ...34 3 It also provides reassurance to the user and service provider that the unit will continue to monitor its local environment and will generate warning messages should an issue arise What should be...

Страница 46: ...nction only works for telecare sensors and events when they are configured not to raise an alarm call The time when messages can be played can also be controlled using the Times when Voice announcer m...

Страница 47: ...hen the alarms will be enabled Outside these times the particular alarm event will be inhibited depending upon the action selected Block event alarms outside window The unit will not dial the monitori...

Страница 48: ...telephone calls using either Caller Line Identification CLI or non CLI The home unit can also be programmed via PC Connect to answer the call as either a normal telephone call POTS or with the remind...

Страница 49: ...er the virtual sensor also provides the ability to extend the time period if user activity is detected elsewhere in the property e g client has gone downstairs to make a drink therefore reducing false...

Страница 50: ...Determine the telephone number s of the PNC5 6 which will be used to receive the ADLife data from the unit This may be the same PNC5 6 that normal alarm calls are sent to but can be a different PNC5...

Страница 51: ...ent PNC5 6 than normal alarm calls it is necessary to set up the alarm numbers and call sequence for ADLife calls This is done in the standard way using PC Connect a Click on the Telephone Numbers and...

Страница 52: ...nts Configuration icon on the main PC Connect screen the Event Configuration screen will open Click the Misc tab and select the ADLife Data option and then click configure This will open the ADLife Da...

Страница 53: ...ges g Set the correct time date on the unit using the Time and Date icon on the main PC Connect screen h Click Write then either Write only modified parameters or Write all parameters except date and...

Страница 54: ...d 71 Garage 1 21 Master bedroom 72 Garage 2 22 Second bedroom 73 Front garden 23 Other bedroom 74 Back garden 24 Other bedroom 75 6 Epilepsy 25 6 ROM 1 event 1 76 6 Epilepsy spare 26 6 ROM 1 event 2 7...

Страница 55: ...er bedroom 07 Bedroom 1 master 28 Other bedroom 07 Bedroom 1 master 29 Other bedroom 07 Bedroom 1 master 30 Bathroom WC 17 Bathroom main 31 Main bathroom 17 Bathroom main 32 Second bathroom 18 Bathroo...

Страница 56: ...specified 00 No location information 99 Unspecified 00 No location information Table 3 Trigger Type Codes Trigger Type Code Trigger Type Code Personal ALB 01 Carer Trigger 15 Personal AP 02 ROM 1 16 T...

Страница 57: ...ALB 016 Smoke 06 Fault status alarm not active A9 Smoke Detector AP Fail 016 Smoke 06 Fault status alarm not active AO Smoke Detector AP Restore 016 Smoke 04 In service fault rectified AQ Door Usage...

Страница 58: ...default Bo Fall Detector Fall LB 021 Fall trigger 1 07 Low battery status set LK Fall Detector Not Worn 021 Fall trigger 1 00 Normal default Lk Fall Detector Not Worn LB 021 Fall trigger 1 07 Low bat...

Страница 59: ...ROM 4 AP Restore 010 Fixed trigger 1 04 In service fault rectified CN Natural Gas Detector activation 027 Natural Gas 00 Normal default Cn Natural Gas Detector activation LB 027 Natural Gas 07 Low bat...

Страница 60: ...DI Epilepsy Sensor other 042 Seizure 00 Normal default Di Epilepsy Sensor other LB 042 Seizure 07 Low battery status set DJ Epilepsy Sensor AP 042 Seizure 08 Busy Dj Epilepsy Sensor AP LB 042 Seizure...

Страница 61: ...0 Fixed trigger 1 00 Normal default IL Warden Panic Alarm 023 Personal attack 1 00 Normal default Il Carer Arrived 091 Service call 00 Normal default IM Carer Non Arrival 091 Service call 09 Out of Se...

Страница 62: ...Normal default K2 Intruder system disarmed 057 System status 00 Normal default K3 Carer Left 099 Service incompleted 00 Normal default K4 Intruder Timeout 057 System status 00 Normal default K5 Keyle...

Страница 63: ...ification 0 to 80 storage relative humidity non condensing 0 to 93 Standards EMC AS NZS CISPR 22 2009 Safety AS NZS 60950 1 2011 Telecoms PTC200 2006 AS CA S002 2010 AS ACIF S004 2008 Radio AS NZS 426...

Отзывы: