Quick Codes
The Tunstall Vi+ home unit has a number of quick codes that can be entered into the
series telephone when the home unit is in programming mode or remotely via PNC4
(v2.5.1) and PNC5/6.
Quick
Code
Purpose
Comments
2040
Reset to default but retain radio triggers
Time and date remain unchanged
2050
Reset to factory defaults
Time and date remain unchanged
2060
Delete ALL radio triggers
Restores to default
3000
Delete the next radio trigger transmitted
Must activate trigger
3011
Activate external relay for 2 seconds
All alarms (Call Raised)
3012
Activate external relay for all alarms when call
selected and de-activate when calls cleared
Call Selected
Call Cleared
3013
Activate external relay on radio smoke alarm
and de-activate when cleared
Smoke Alarm
Call Cleared
3014
Disable external relay for all events
3020
Announce date and time
31xx
Enables periodic calls (30 day) with offset of xx
hours
3100
Disables periodic calls
3300
Demonstrates the pendant test reminder
function
4zxx
Set the last registered trigger for zone and
location
Must be done before exiting
program mode where z = 0 for zone
1 and 1 for zone 2, xx = TT21
location code, see table 1
45xx
Set hardwire input to trigger type number
Where xx trigger type code, see
table 2
46xy
Set hardwired input sensor
x = 0 for disable, 1 = n/o, 2 = n/c
y = 1 for zone 1 and 2 = zone 2
47xx
Set hardwired input location
Where xx is TT21 location code,
see table 1
48xy
Set destination
Where x is telephone number 1 to
10 ( 0 = 10 ) y = 0 for CC, 1 for PR
and 2 for POTS
51xx
Enable inactivity monitoring for a period of 12 or
24 hrs
Where xx is 12 or 24
6001
Enable intruder
Default entry/exit time 30 secs
6002
Disable intruder
6003
Set last assigned trigger as a Zone 1 armer
Home unit must be in assign mode
6004
Set last assigned trigger to be a Bogus Caller
Home unit must be in assign mode
6005
Set last assigned trigger to be a Zone 1 and
Zone 2 armer
Home unit must be in assign mode
6006
Set last assigned trigger to be Zone 1 and Zone
2 arm/disarmer
Home unit must be in assign mode
6008
Set last assigned trigger to start entry/exit tones
on activation
Home unit must be in assign mode
6009
Set last assigned trigger to not start entry/exit
tones on activation
Home unit must be in assign mode
61xx
Enable intruder and set entry/exit tones
Where xx is in seconds
6413
Enable intruder disarm method of AWAY and
personal trigger