EXICALL

®

 

Emergency and Information Telephone NIT 960 

Article Number: 121.5000 

 

  Caution! 

For emergency use, connect EXICALL

®

 NIT 960 to a 

direct exchange line

whenever possible. This 

ensures that emergency calls can still be made in the 
event of a power failure (failure of the subscriber's 
switchboard or internal telephone exchange). 

 

Programming can be performed only with the exchange 

line and power supply connected! 

See pages 5 and 6 for instructions 

 

New:  Remote control 

(standard from 

s/n 1000 onwards)

 

(10 commands possible during the call, 
*additional contact K3, plus remote hang-up

)

 

7 pulse lengths from 2-8 seconds* 
1 pulse, held until end of call * 
1 test, acknowledgement contact 
1 remote call termination 

New:  Seizure relay option 

(separate box, contact K4)

 

1 floating contact output, 
   closed when seized 

New:  Day/night switch 

(additional function: ext. ack. contact K2)

 

Choice of separate day/night 
telephone numbers., selectable via 
a floating contact 

New:  Explosion protection 

(Zone 2, T1 - T6, SW27)

 

SEV/ESI certificate A.no.96.1 10403
Ex-classification Ex nVL IIC T6 

Description pages 7 and 8 

Brief Tech. Description 

 

Copyright © 1997 Studer K+I, CH-3074 Muri BE. All rights reserved. 

Summary of Contents for EXICALL NIT 960

Page 1: ...hange Programming can be performed only with the exchange line and power supply connected See pages 5 and 6 for instructions New Remote control standard from s n 1000 onwards 10 commands possible during the call additional contact K3 plus remote hang up 7 pulse lengths from 2 8 seconds 1 pulse held until end of call 1 test acknowledgement contact 1 remote call termination New Seizure relay option ...

Page 2: ...h PC no 30 7032 0 MWSt no 367 246 Gewerbekasse in Bern Table of Contents Chapter Page 1 EXICALL Technical Data 3 2 Customised EXICALL Programming 5 3 EXICALL Local Programming 6 4 EXICALL Remote Programming 6 5 Additional Functions and Modifications for software version V02 22 7 6 Remote Control terminal assignment and function description 7 7 Seizure Relay Option function description 8 8 Day Nigh...

Page 3: ...etup initiated at 11V 60V DC or 11V 42V AC Environmental conditions Temperature 0 50 C Humidity 20 70 rel humidity Casing Dimensions 80 x 268 x 41mm B x H x D Weight Approx 750g Approvals Switzerland BAKOM no 94 0759 T N Germany Netherlands Telephone line Switzerland Type a b analogue Equivalent circuit for a b impedance 820 Ohm 220 Ohm 115 nF a b Dialling mode Pulse or DTMF touch tone External li...

Page 4: ...ine Using tone dial telephone and spoken prompts G F I E Security protection Password Call set up Preset numbers 2 Max digits per telephone no 17 1 PBX access code digit 16 digit telephone no Setup procedure Selectable line seizure dial 1st preset number line seizure PBX code dial 1st preset number line seizure only Initiate call setup using call button Selectable immediate 0 5 3 5 seconds delay p...

Page 5: ... No 2 Language sel 1 LCD display 1 German X 2 French 3 Italian 4 English 5 rotating 2 Synth voice 1 German X 2 French 3 Italian 4 English 3 Identification 1 ID number X max 16 digits 0 2 Output type 1 Synth voice 2 DTMF dialling 3 No ident X 4 Dialling mode 1 Pulse dialling 2 DTMF dialling X 5 Ext disabling 1 Active 2 Not active X 6 Call set up 1 Immediate X After selections EXICALL No 2 0 5 s 2 8...

Page 6: ... Enter menus select 1 Escape stop ESC 1 Select Browse 7 delete line DEL Attention All the parameters can be changed only in the status enter column with the exception of language selection for programming which must be done after entering the password Programming is carried out according to chapter 2 Customised EXICALL Programming page 5 4 EXICALL Remote Programming 1 Connect EXICALL to an exchang...

Page 7: ...set to 1 off in programming item no 282 Attention If incoming calls are disabled using the method described above remote programming of EXICALL is no longer possible 6 Remote Control Option 6 1 Remote control operation Remote control by the called party is possible by issuing the following commands during a call only possible from a touch tone dial telephone Cmd Contact K3 closes Password Cmd Cont...

Page 8: ...ssignment relay a b 12V AC or DAY NIGHT switch open day 1st number 7 Seizure Relay Option A seizure relay is available as an additional component inserted in series with the a b connection The floating output contact K4 is closed from the time the key is pressed until the end of the call 8 Day Night Switch Option EXICALL can now be programmed via menu item no 143 so that the ext C A contact K2 is ...

Reviews: