![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327078.webp)
Settings
66
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x2052
0
Motor Voltage Class
-
0~0x00000001
0
Restart
Y
Set the voltage level of the motor.
Byte0: Motor voltage class
0x00-AC200V;
0x01-AC400V.
Byte1, Byte2, Byte3: Reserved
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x2053
0
Motor Rated Speed
rev/min
1~100000
3000
Restart
Y
Set the rated speed of the motor.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x2054
0
Motor
Wire
Winding
Resistance
mΩ
1~4294967295
30300
Restart
Y
Wire winding resistance = phase winding resistance ×2.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x2055
0
Motor
Wire
Winding
Inductance
uH
1~4294967295
34000
Restart
Y
Wire winding inductance = phase winding inductance ×2.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x2056
0
Motor Rotor Inertia
mkg*cm
^2
1~4294967295
50
Restart
Y
Set the inertia of the motor rotor rotation.
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x2057
0
Motor Back EMF
mV/rpm
1~10000
56
Restart
Y
Set motor Back-EMF coefficient
Содержание CoolDrive Series
Страница 1: ...CoolDrive Series Smart 7 Servo Drive User Manual Model CDS7S EtherCAT interface Document Version R1 ...
Страница 29: ...Preface 17 T2 model ...
Страница 30: ...Preface 18 T3 model ...
Страница 31: ...Preface 19 T4 model ...
Страница 230: ...Monitoring 218 ...