![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327102.webp)
Settings
90
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x608B
0
Velocity Notation Index
-
0~0x00FF
0
Restart
Y
Set the velocity unit notation index.
Byte0: Velocity notation index selection
0x03-×1000;
0x01-×10;
0x00-×1;
0xFF-×0.1;
0xFE-×0.01;
0xFD-×0.001;
0xFA-×0.000001;
For example: if 0x6089=0xFD, 0x608A=0x01, 0x608B=0x01, the position unit is set to mm, while the velocity unit is set to
10*mm/s.
The velocity dimension index is the same as the position unit dimension index per second. Only the velocity notation index
can set.
Byte1, Byte2, Byte3: Reserved
Index
Sub-ind
ex
Name
Unit
Setting range
Default
value
effective
Period
0x608D
0
Acceleration Notation
Index
-
0~0x00FF
0
Restart
Y
Set the acceleration unit notation index.
Byte0: Acceleration notation index selection
0x03-×1000;
0x01-×10;
0x00-×1;
0xFF-×0.1;
0xFE-×0.01;
0xFD-×0.001;
0xFA-×0.000001;
For example: if 0x6089=0xFD, 0x608A=0x01, 0x608B=0x01, the position unit is set to mm, while the acceleration unit is set
to 10*mm/s^2.
The acceleration dimension index is the same as the position unit dimension index per second square. Only the acceleration
notation index can set.
Byte1, Byte2, Byte3: Reserved