Maintenance
258
Number
Alarm name
Alarm
code
Possible causes
Solutions
5.
The internal circuit of the
drive is abnormal
or extend the EtherCAT
communication cycle
4.
When
the
real-time
requirement is not high,
increase the set value of the
servo parameter 0x21B1
properly
5.
Modify the underlying DC
synchronization mechanism
of the upper computer
EtherCAT master station to
ensure that the RxPDO data
sent by the upper computer
is at least 100 us ahead of
the
DC
synchronization
signal
6.
Replace the drive
72.
Interface
encoder
resolution changed
0xFF52
The current resolution of the
interface encoder of the drive is
not the same as the resolution of
the interface encoder saved at
the last power-off
Restart the drive
73.
First
encoder
overheating
0xFF53
1.
The temperature sampling
circuit inside the drive is
abnormal
2.
The temperature of the
drive's
operating
environment is beyond the
allowed range
1.
Lower
the
ambient
temperature, for example,
by improving the cabinet's
cooling conditions
2.
Replace the drive
74.
First encoder battery
undervoltage alarm
0xFF54
1.
The encoder is not externally
connected to a battery or
the battery wiring is poor
2.
The encoder battery is
under-voltage
1.
Check the wiring of the
encoder battery and make
sure the wiring is reliable
2.
Replace the battery
3.
Execute
the
encoder
multi-turn reset command
4.
If not needed, the encoder
battery
under-voltage
detection function can be
disabled
via
the
servo
parameter 0x201B
Содержание CoolDrive Series