Safety features
273
Improper use may lead to personal accidents. Assess risks to ensure safety even in the above situations.
STO action sequence
11.5
Diagram of STO action sequence under normal operation of servo drive:
STO input
Motor speed
trigger
Not triggered
Disable PWM
output
Disable PWM
output
Enable PWM
output
Enable PWM
output
Software
control
PWM state
Hardware
control
PWM state
STO fault detection monitoring (EDM)
11.6
The fault detection monitoring (EDM) output is used to monitor the signal of any wiring fault between the STO circuit or
safety device and the STO input. The relationship between STO input signal and fault detection monitoring output is shown in
the table below.
Signal name
Logical relationship
STO1 input
ON
ON
OFF
OFF
STO2 input
ON
OFF
ON
OFF
EDM output
OFF
OFF
OFF
ON
When the STO2 input signal is set to OFF, the EDM output signal will be ON within a maximum of 6 ms when the safety
function is enabled.
STO input
trigger
Not triggered
max 6ms
Optocoupler
disconnect
Optocoupler
closed
EDM output