![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327062.webp)
Wiring
50
DO Wiring
Controller
CDS7S
Among them, DO3 can be used to control the motor holding brake. When in use, it is prohibited to connect DO3 directly
with the motor holding brake. An intermediate relay must be used for this purpose, as shown in the figure below.
M
11
12
relay
Motor brake
DC24V
DO3+
DO3-
DO3 control motor brake
Note:
1.When the DO controls the motor brake, the safety brake
function (X12 port) is invalid.
2.The brake coil must be connected to the freewheeling
diode for protection.
DC24V
KA
X7
CDS7S
When the motor brake control output mode is set to the ordinary mode, DO3 must be configured as the
motor brake control simultaneously; when the motor brake control output mode is set to the safe mode,
DO3 cannot be configured as the motor brake control.