![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 217](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327217.webp)
Monitoring
205
Relevant Parameters
9.1.2
Relevant parameters of OLED screen
Relevant parameters of [OLED screen] are as follows.
Index
Name
Unit
Setting range
Default value
Effective
Period
0x2088
OLED Display Settings
—
0-0xFF070301
0x00050000
Restart
Y
0x2089
OLED Display Content Settings 1
—
0-0x1F1F1F1F
0x04030201
Restart
Y
0x208A
OLED Display Content Settings 2
—
0-0x1F1F1F1F
0x0A070605
Restart
Y
0x208B
OLED Display Content Settings 3
—
0-0x1F1F1F1F
0
Restart
Y
0x208C
OLED Display Content Settings 4
—
0-0x1F1F1F1F
0
Restart
Y
The parameter [OLED display settings] (0x2088) is used to set such items as the language of display, screen-off time and
cyclic display etc., which are defined in detail as follows.
Byte
Functions
Set value
Corresponding settings
Byte 0
Reserved
——
——
Byte 1
Display language
0x00
Simplified Chinese
0x01
English
Byte 2
Screen-off settings
0x00
Constantly on
0x01
Going off after 1 minute
0x02
Going off after 5 minutes
0x03
Going off after 10 minutes
0x04
Going off after 20 minutes
0x05
Going off after 30 minutes
Byte 3
Cyclic
display
settings
0x00
No cyclic display
0x01
Cyclic display at an interval of 3 s
0x02
Cyclic display at an interval of 5 s
0x03
Cyclic display at an interval of 10 s
0x04
Cyclic display at an interval of 15 s
0x05
Cyclic display at an interval of 20 s
0x06
Cyclic display at an interval of 30 s
0x07
Cyclic display at an interval of 60 s
0x08
Cyclic display at an interval of 120 s
0x09
Cyclic display at an interval of 180 s
0x0A
Cyclic display at an interval of 360 s
1.
If Byte 2 is set to an option other than 0x00 and the button is not operated within the set time, the
screen will automatically go out, but it can be waken up by clicking the button.
2.
If Byte 3 is set to an option other than 0x00, the displayed content will be switched at the set time
interval, and the screen will cyclically show the content set by parameters 0x2089, 0x208A, 0x208B