![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 213](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327213.webp)
Application functions
201
Digital input and output function
8.9
Overview
8.9.1
The [digital input and output] function is used for the information exchange between the servo drive and external devices.
This section mainly introduces the relevant parameters and configuration mode of this function. As for the external wiring of the
digital input and output function, refer to section [Wiring].
Relevant Parameters
8.9.2
The relevant parameters of the [digital input and output function] are as follows.
Index
Name
Unit
Setting range
Default value
effective Period
0x20C3
DI Functions Selection 1
—
0-0x8F8F8F8F
0
Restart
Y
0x20C4
DI Functions Selection 2
—
0-0x8F8F8F8F
0
Restart
Y
0x20C5
DO Functions Selection
—
0-0x8F8F8F8F
0
Restart
Y
0x21E6
Remote DO Default Setting
—
0-0x01010101
0
Restart
Y
[DI Functions Selection 1] is used to set the signal distribution of digital inputs DI1 - DI4, and [DI Functions Selection 2] is
used to set the signal distribution of digital inputs DI5 and DI6. The set values and corresponding functions of each byte are
shown below.
Set value
Signal function
0x00
Disabled
0x01
Positive limit switch, switch off is active
0x02
Negative limit switch, switch off is active
0x03
Home switch, switch off is active
0x04
TouchProbe 1, switch off is active (DI1, DI2); Reserved (DI3 - DI6)
0x05
TouchProbe 2, switch off is active (DI1, DI2); Reserved (DI3 - DI6)
0x06
Emergency stop switch, switch off is active
0x07
Remote input, switch off is active
0x08
Fault reset, switch off is active
0x09
Dynamic brake switch, switch off is active
0x0A
Retract switch, switch off is active
0x0B
Synchronous data trace input
0x81
Positive limit switch, switch on is active
0x82
Negative limit switch, switch on is active
0x83
Home switch, switch on is active
0x84
TouchProbe1, switch on is active (DI1, DI2); Reserved (DI3 - DI6)
0x85
TouchProbe2, switch on is active (DI1, DI2); Reserved (DI3 - DI6)
0x86
Emergency stop switch, switch on is active
0x87
Remote input, switch on is active
0x88
Fault reset, switch on is active