![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 272](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327272.webp)
Maintenance
260
Number
Alarm name
Alarm
code
Possible causes
Solutions
80.
Motor blockage
0xFF60
1.
The mechanical load is stuck
or stalled
2.
The motor brake is not
released
1.
Check
for
mechanical
jamming
2.
Check whether the braking
circuit is normal
81.
Motor overheating
0xFF61
1.
The temperature sampling
circuit inside the drive is
abnormal
2.
The temperature of the
motor's
operating
environment is beyond the
allowed range
1.
Lower
the
ambient
temperature, for example,
by improving the motor's
cooling conditions
2.
Replace the motor or drive
82.
Incremental encoder Z
signal abnormal
0xFF62
1.
The wiring of the motor
encoder is abnormal (such as
broken line, cold solder joint)
2.
The encoder line is disturbed
1.
Check the wiring of the
motor encoder and make
sure that the wiring is
standard and correct
2.
Add magnetic rings to the
cable of the encoder and the
power cable of the motor
83.
EEPROM data write
failed
0xFF63
1.
The internal circuit of the
drive is abnormal
2.
The drive is disturbed
1.
Replace the drive
2.
Restart
the
drive,
and
enhance
the
drive's
anti-interference measures
84.
EEPROM data read
failed
0xFF64
1.
The internal circuit of the
drive is abnormal
2.
The drive is disturbed
1.
Replace the drive
2.
Restart
the
drive,
and
enhance
the
drive's
anti-interference measures
85.
Regeneration
brake
circuit abnormal
0xFF65
1.
Regeneration
braking circuit
exception
2.
The
regeneration
braking
circuit is disturbed
1.
Replace the drive
2.
Enhance
the
drive's
anti-interference measures
86.
Brake control circuit
abnormal
0xFF66
1.
The motor braking output is
open-circuited
2.
The motor braking output is
short-circuited
3.
The 24V power of the motor
brake is under-voltage
4.
The motor braking output is
overloaded
5.
The internal braking circuit
of the drive is abnormal
1.
Check whether the wiring of
the braking circuit is normal
2.
Check whether the voltage
of the 24V power of the
motor brake is normal
3.
Replace the drive