![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 159](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327159.webp)
Adjustment
147
Basic mode gain adjustment
7.6
Overview
7.6.1
When adopting basic mode gain adjustment, the user can adjust parameters such as position loop proportional gain,
velocity loop proportional gain, velocity loop integration time constant and torque command low pass filter cutoff frequency
respectively to complete the adjustment of system response characteristics.
Velocity
Associated parameters
7.6.2
The parameters related to basic mode gain adjustment are shown in the following table.
Index
Name
Unit
Setting range
Default value
effective
Period
0x21C6
Regulator Basic Control Setting
—
0x00000000-0x00000003
0x00000001
Restart
Y
0x20C0
Inertia Ratio Setting
%
0-5000
100
Restart
Y
0x2160
Position
Loop
Proportional
Gain1
0.001
0-3000000
1000
Immediately
Y
0x2163
Position
Loop
Proportional
Gain2
0.001
0-3000000
1000
Immediately
Y
0x2161
Positioin Loop Integration Time
Constant 1
μs
125-1000000
1000000
Immediately
Y
0x2164
Positioin Loop Integration Time
Constant 2
μs
125-1000000
10000
Immediately
Y
0x2165
Velocity
Loop
Proportional
Gain1
0.001
1-1000000
6000
Immediately
Y
0x2167
Velocity
Loop
Proportional
Gain2
0.001
1-1000000
4000
Immediately
Y
0x2166
Velocity Loop Integration time
Constant1
μs
125-1000000
10000
Immediately
Y
0x2168
Velocity Loop Integration Time
Constant2
μs
125-1000000
15000
Immediately
Y