![Tsino Dynatron CoolDrive Series Скачать руководство пользователя страница 201](http://html.mh-extra.com/html/tsino-dynatron/cooldrive-series/cooldrive-series_user-manual_1178327201.webp)
Application functions
189
Position comparison output
8.6
Overview
8.6.1
The [position comparison output] function is used to output pulse signal through the DO terminal of the servo drive when
the actual position passes the position set by the parameter.
Associated parameters
8.6.2
The parameters for setting the [position comparison output] function are as follows.
Index
Name
Unit
Setting range
Default
value
effective
Period
0x2030
Position Compare Output Pulse
Width
0.1 ms
0 - 65535
100
Restart
Y
0x2031
Position
Compare
Output
Compensation Time
0.1 μs
-32767 - 32767
0
Restart
Y
0x2032
Position Compare Output Assign
Setting
—
0 - 0x03030303
0
Restart
Y
0x2033
Position Compare Output Value 1
PosUnit
-2147483648 -
2147483647
0
Immediately
Y
0x2034
Position Compare Output Value 2
PosUnit
-2147483648 -
2147483647
0
Immediately
Y
0x2035
Position Compare Output Value 3
PosUnit
-2147483648 -
2147483647
0
Immediately
Y
0x2036
Position Compare Output Value 4
PosUnit
-2147483648 -
2147483647
0
Immediately
Y
0x2084
Position
Comparison
Output
Mode
—
0 - 0x03030303
0
Restart
N
1.
Byte0, Byte1, Byte2 and Byte3 of the [Position Compare Output Assign Setting] correspond to the
output terminal distribution settings of position comparison values 1 - 4 respectively. The setting
options of each byte are as follows: 0x00: invalid output; 0x01: DO1; 0x02: DO2; 0x03: DO3.
Note that if DO1, DO2 and DO3 have been set to other functions via 0x20C5 (DO Functions
Selection), they can no longer be set to position comparison output. Only when DO1, DO2 and DO3
are disabled via 0x20C5, can corresponding ports be used as position comparison output.
2.
The unit of the [Position Compare Output Value] is determined by 0x6089 and 0x608A.
3.
The [Position Comparison Output Mode] is used to specify the polarity of output pulse. Byte0,
Byte1 and Byte2 correspond to the polarity of output pulse of position comparisons DO1, DO2 and
DO3 respectively. The configuration options of each byte are: 0x00: positive pulse; 0x01: negative
pulse.
4.
For positive pulse output, the output transistor is OFF; for negative pulse output, the output
transistor is ON.