Wiring
33
Three-phase AC 220 V power supply input
Port name
Pin symbol
Specifications and parameters
Power supply input port (X1)
L1, L2, L3
Three-phase AC 200V~240V
,
-15%~+10%; 50/60 Hz
Control power and regenerative
braking port (X3)
L1C, L2C
Single-phase AC 220 V, ± 15%; 50/60 Hz
B, RB, P
When using the built-in regenerative resistor, short circuit interfaces B
and RB, and do not use interface P.
(Not supported by T1 model)
When an external regenerative resistor is connected, connect it to
interfaces B and P, and do not use interface RB.
DC bus port (X4)
P1, N
Do not use
Ground terminal
Connect with external circuit ground terminal
Single-phase AC 220 V power supply input (only supported by T1 and T2 models)
Port name
Pin symbol
Specifications and parameters
Power supply input port (X1)
L1, L2
Single-phase AC 200V~240V
,
-15%~+10%; 50/60 Hz, do not use L3
Control power and regenerative
braking port (X3)
L1C, L2C
Single-phase AC 220 V, ± 15%; 50/60 Hz
B, RB, P
When using the built-in regenerative resistor, short circuit interfaces B
and RB, and do not use interface P.
(Not supported by T1 model)
When an external regenerative resistor is connected, connect it to
interfaces B and P, and do not use interface RB.
DC bus port (X4)
P1, N
Do not use
Ground terminal
Connect with external circuit ground terminal
DC power supply input (optional)
Port name
Pin symbol
Specifications and parameters
Power supply input port (X1)
L1, L2, L3
Do not use
Control power and regenerative
braking port (X3)
L1C, L2C
Single-phase AC 200V~240V
,
-15%~+10%; 50/60 Hz
B, RB, P
When using the built-in regenerative resistor, short circuit interfaces B
and RB, and do not use interface P.
(Not supported by T1 model)
When an external regenerative resistor is connected, connect it to
interfaces B and P, and do not use interface RB.
DC bus port (X4)
P1, N
DC 310V
,±
15%, with the positive pole of the power supply connected
to P1 and the negative pole of the power supply to N
Ground terminal
Connect with external circuit ground terminal
When using DC power supply input, X1 port is prohibited from wiring. Otherwise, the device
will be damaged