10.
System configuration
If the combination of devices connected to the system control is
changed, the new system configuration must then be entered
via the web-based user interface.
10.1 Setting the system configuration
Conditions
■
Operation via web-based user interface
■
Devices (AC-DC module, DC-DC modules) are connected to
the system control
1. To switch on the system control and the modules: switch on
the 24 V supply voltage.
1
Most recently saved configura-
tion is displayed as the sug-
gested value.
2
Most recently saved configura-
tion
3
Most recently saved configura-
tion does not match the
detected configuration.
Input screen "System Configuration"
Fig. 7-13
The input screen "System configuration" is displayed.
The connected devices do not match the expected configura-
tion, i.e. the most recently saved configuration.
Status LEDs on the system control: All 3 LEDs flash syn-
chronously.
Status LEDs on the DC-DC module: The green and red
LEDs light up and the yellow LED flashes.
2. In "Select configuration", select the present system configura-
tion:
A67-0140-00.BKen-0
01-05
2020-07-01
System configuration
7
‐
29
Содержание TruConvert DC 1000 Series
Страница 1: ...Operator s manual TruConvert DC series 1000 TruConvert System Control TruConvert Modular...
Страница 2: ......
Страница 6: ...II Good to know 2020 07 01 A67 0140 00 BKen 0 01 05...
Страница 36: ...3 12 Technical data dependent on device variant overview 2020 07 01 A67 0140 00 BKen 0 01 05...
Страница 38: ...7 Ethernet 4 10 8 RS 485 4 11 4 2 Interfaces 2020 07 01 A67 0140 00 BKen 0 01 05...
Страница 40: ...Fig 4 3 4 4 Protective earth TruConvert DC series 1000 2020 07 01 A67 0140 00 BKen 0 01 05...
Страница 48: ...4 12 RS 485 2020 07 01 A67 0140 00 BKen 0 01 05...
Страница 54: ...5 6 CSA certification 2020 07 01 A67 0140 00 BKen 0 01 05...
Страница 106: ...16 State diagram State machine Fig 7 19 7 38 State diagram 2020 07 01 A67 0140 00 BKen 0 01 05...