5.
Possible installation positions
Possible orientations in horizontal position
Fig. 6-2
Operation in a horizontal position is permitted without restrictions.
1
Cooling air
Possible orientation in vertical position
Fig. 6-3
Operation in a vertical position is only permitted under the follow-
ing conditions:
■
The cooling air moves in the upwards direction.
■
Installation of a collection tray under the DC-DC module.
The collection tray must prevent any glowing parts from the
device from dripping onto a flammable base. The collection
tray therefore fulfils the function of a fire protection housing.
A67-0140-00.BKen-0
01-05
2020-07-01
Possible installation positions
6
‐
7
Horizontal position
Vertical position