e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 134
<<Pixel counter related code>>
(Chap. 2.2.9)
Setting mode (08) <e-STUDIO350/450>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
1500
Pixel
counter
Standard paper size setting
ALL
EUR: 0
UC: 1
JPN: 0
<0-1>
SYS
Selects the standard
paper size to convert it
into the pixel count (%).
0: A4
1: LT
1
1501
Pixel
counter
Pixel counter all clearing
ALL
-
SYS
Clears all information
related to the pixel
counter.
3
1502
Pixel
counter
Service technician refer-
ence counter clearing
ALL
-
SYS
Clears all information
related to the service
technician reference
pixel counter.
3
1503
Pixel
counter
Toner cartridge reference
counter clearing
ALL
-
SYS
Clears all information
related to the toner car-
tridge reference pixel
counter.
3
1504
Pixel
counter
Pixel counter display set-
ting
ALL
1
<0-1>
SYS
Selects whether or not
to display the pixel
counter on the LCD
screen.
0: Displayed
1: Not displayed
1
1505
Pixel
counter
Displayed reference set-
ting
ALL
0
<0-1>
SYS
Selects the reference
when displaying the
pixel counter on the
LCD screen.
0: Service technician
reference1: Toner
cartridge reference
1
1506
Pixel
counter
Toner empty determination
counter setting
ALL
0
<0-1>
SYS
Selects the counter to
determine toner empty.
0: Output pages
1: Pixel counter
1
1507
Pixel
counter
Threshold setting for toner
empty determination (Out-
put pages)
ALL
400
<0-999>
SYS
Sets the number of out-
put pages to determine
toner empty. This set-
ting is valid when “0” is
set at 08-1506.
1
1508
Pixel
counter
Threshold setting for toner
empty determination (Pixel
counter)
ALL
17550
<0-
60000>
SYS
Sets the number of out-
put pages to determine
toner empty. This set-
ting is valid when “1” is
set at 08-1506.
1
1509
Pixel
counter
Pixel counter clear flag/
Service technician refer-
ence
ALL
0
<0-1>
SYS
Becomes “1” when 08-
1502 is performed.
2
1510
Pixel
counter
Service technician refer-
ence cleared date
ALL
-
SYS
Displays the date on
which 08-1502 was per-
formed.
2
1514
Pixel
counter
Toner cartridge reference
cleared date
ALL
-
SYS
Displays the date on
which 08-1503 was per-
formed.
2
1518
Pixel
counter
Toner cartridge reference
count started date
ALL
-
SYS
Displays the date on
which 08-1503 was per-
formed.
2
05/12
Содержание e-Studio 350
Страница 6: ......
Страница 436: ...e STUDIO350 352 353 450 452 453 2003 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 36 ...
Страница 576: ...e STUDIO350 352 353 450 452 453 2003 2008 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 140 ...
Страница 763: ......
Страница 764: ......