e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 32
(9) Rotate the lever of the drum shaft and
release the lock. Then pull out the drum
shaft.
Fig. 3-19
(10) Take off the drum.
Fig. 3-20
(11) Press down the drum cleaning blade and fix
the blade with the blade releasing jig so that
it will not rebound.
Note:
Note:
Do not touch the edge of the drum cleaning
blade.
Fig. 3-21
Drum shaft
lever
Drum shaft
Drum
Blade
releasing jig
Cleaning blade
Содержание e-Studio 350