© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3 - 55
3
(9) Open the RADF to tighten 2 hand screws.
Close the RADF and then check again that
the positioning pins fit smoothly into the
holes on the RADF.
Fig. 3-63
(10) Fit the hinge hole into the hole of the equip-
ment at the rear right of the RADF to tighten
the stepped screw. If they do not fit, adjust
the position of the hole by turning the screw
of the adjustment plate.
Fig. 3-64
(11) Tighten the stepped screw and 2 screws on
the adjustment plate. Open and close the
RADF to check again that the positioning
pins fit smoothly into the holes on the RADF.
Remove the positioning pins after checking
it. (Replace the positioning pins at the rear of
the right-hand hinge of the RADF.)
Fig. 3-65
Screw
Stepped Screw