e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3 - 57
3
3.10.2
Adjustment of RADF height
It is mainly performed at the installation. It is also required when the RADF is dislocated for some rea-
son such as moving the equipment.
Perform the following adjustment by using the screw of the left and right hinge.
Note:
Note:
Perform this adjustment after “3.10.1 Adjustment of RADF position”.
Turn the exposure lamp ON during the gap check. (Test Mode: 03-267)
(1) Adjustment standard
Adjust the height so that the platen guide front holder touches the ADF original glass.
Adjust the height so that the gap between the platen guide rear holder and the ADF original glass
becomes 0.5 mm ± 0.3.
Fig. 3-67
(2) Adjust the height by turning the height
adjusting screw on the left hinge.
Clockwise: The height of the hinge becomes
high.
Counterclockwise: The height of the hinge
becomes low.
Fig. 3-68
0.5mm±0.3
0mm
Platen guide
rear holder
ADF original glass
Platen guide
front holder