e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 118
783
Mainte-
nance
Remote-controlled service
polling day selection Day-4
ALL
0
<0-31>
SYS
0: OFF
1 to 31:
1st to 31st of a
month
1
784
Mainte-
nance
Remote-controlled service
polling day selection Sun-
day
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
785
Mainte-
nance
Remote-controlled service
polling day selection Mon-
day
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
786
Mainte-
nance
Remote-controlled service
polling day selection Tues-
day
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
787
Mainte-
nance
Remote-controlled service
polling day selection
Wednesday
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
788
Mainte-
nance
Remote-controlled service
polling day selection
Thursday
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
789
Mainte-
nance
Remote-controlled service
polling day selection Friday
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
790
Mainte-
nance
Remote-controlled service
polling day selection Satur-
day
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
794
Mainte-
nance
Information of supplies set-
ting of toner cartridge K
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
795
Mainte-
nance
Information of supplies set-
ting of toner bag
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
796
Mainte-
nance
Remote-controlled service
lengthened interval polling
(End of month)
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
797
Mainte-
nance
Firmware download
ALL
0
<0-1>
SYS
0: Accepted
1: Prohibited
1
798
General
Notifying address of trialp-
eriod end
PRT/
SCN
3
<0-3>
SYS
Sets where the end of
the trial period is to be
notified.
0: OFF
1: User
2: Service center
3: User and service
center
1
799
General
Forcible end of trial period
PRT/
SCN
-
SYS
[CANCEL]: Cancel
[EXECUTION]: Forc-
ible end
When the “Forcible end
of trial period” is per-
formed, “0” is set in the
code (08-673) to end up
the trial period forcibly.
1
826
Charger
Main charger bias correc-
tion (Toner saving mode)
PRT
128<0-
255>
M
Corrects the value of
the main charger bias
adjustment (05-210).
1
840
Image
control
Setting of toner density
temperature control
ALL
0
<0-1>
M
0: Controlled
1: Not controlled
1
Setting mode (08) <e-STUDIO350/450>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
Содержание e-Studio 350
Страница 6: ......
Страница 436: ...e STUDIO350 352 353 450 452 453 2003 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 36 ...
Страница 576: ...e STUDIO350 352 353 450 452 453 2003 2008 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 140 ...
Страница 763: ......