© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
TROUBLESHOOTING
5 - 97
5
[ 2 ] RFC related error
(When GM-1010/3010, GM-2010, GM-1060/4060, GM-2060, GM-1061/4060, GM-2061,
GM-1120/4120, or GM-2120 is installed)
[2500] HOST NAME error (RFC: 500) / Destination mail address error (RFC: 500) / Terminal mail
address error (RFC: 500)
[2501] HOST NAME error (RFC: 501) / Destination mail address error (RFC: 501) / Terminal mail
address error (RFC: 501)
Check if the Terminal mail address and Destination mail address are correct.
Check if the mail server is operating properly.
Turn the power OFF and then back ON. Perform the job in error again.
[2503] Destination mail address error (RFC: 503)
[2504] HOST NAME error (RFC: 504)
[2551] Destination mail address error (RFC: 551)
Check if the mail server is operating properly.
Turn the power OFF and then back ON. Perform the job in error again.
If the error still occurs, replace the NIC board.
[2550] Destination mail address error (RFC: 550)
Check the state of the mail box in the mail server.
[2552] Terminal/Destination mail address error (RFC: 552)
Check the capacity of the mail box in the mail server.
Select “Text “of the original modes for the original data or lower the resolution level and then retransmit.
Or divide the original data into several pieces and retransmit them.
[2553] Destination mail address error (RFC: 553)
Check if there is an illegal character in the mail box in the mail server.