© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3 - 91
3
(3) The tension becomes loose.
While pushing the bracket down, hold the tray and move it up or down, to adjust the angle so that
the tray becomes parallel by a visual check.
Fig. 3-130
(4) After the height adjustment, tighten the fixing screw of the bracket.
Note:
Note:
If the fixing screw of the bracket is not fixed, the belt is loosened which may cause a skipped
tooth.