e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
FIRMWARE UPDATING
6 - 68
[A] Update procedure
Important:
• Do not operate the equipment or send a print job to the equipment during the update. This
interferes the updating operation and the firmware may not be written properly.
• Do not turn OFF the power of equipment or PC during the update. The data could be dam-
aged and not to be continued to function properly.
• When using FSMS, set “1” at FSMS permission code (08-258) in the Setting Mode (08) in
advance.
• The data file (tz file format) of each firmware is recommended to save at the local drive in the
PC (C drive, etc.) where FSMS program is installed.
(1) Connect the equipment and PC with the cable.
* Connect the cable to the RS-232C connector in RS-232C connection after taking off the con-
nector cover of the equipment.
* Connect the PC end of the cable to the USB port or RS-232C port on the PC.
(2) Turn ON the power of the equipment.
Tip:
When updating with FSMS, updating can be performed in any of the normal mode, Adjustment
Mode (05) and Setting Mode (08). To avoid an interruption during the update, using the Setting
Mode (08) is recommended.
(3) Turn ON the power of the PC.
(4) Activate FSMS.
Select “TOSHIBA FSMS” starting with the Start menu.
(5) Enter the login password and click the [OK] button.
* Set the login password at the installation of FSMS.
Fig. 6-65
Fig. 6-66
[USB connection]
[RS-232c connection]
USB connector (device)
USB cable
RS-232C connector
RS-232C cable