e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
FIRMWARE UPDATING
6 - 12
(4) Remove the cover plate.
Fig. 6-8
(5) Connect the download jig with the jig connector (CN100) on the SYS board.
Fig. 6-9
(6) Turn ON the power while [8] button and [9] button are pressed simultaneously.
The screen for selecting the items to be updated is displayed. “*” is displayed next to the items to
be updated. (All items are selected in the default settings.)
Cover plate
Connector