e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
5 - 112
4)Toner offset
Toner offset (Shadow image appears approx. 124 mm toward the dark image.)
Defective area
Step
Check items
Prescription
Density
1
Is the density too high?
Adjust the density.
Fuser unit
2
Is the pressure of the fuser roller
normal?
Check the pressure releasing parts and
pressurization mechanism.
3
Is the thermistor in contact with the
fuser roller?
Contact the thermistor with the fuser roller.
4
Is there a scratch on the fuser roller
surface?
Replace the fuser roller.
5
Has the fuser roller reached its PM
life?
Replace the fuser roller.
6
Is the setting temperature of the
fuser roller normal?
Check the adjustment values of fuser roller
temperature?
08-410:12 (200°C) 08-411:12 (200°C)
Paper
7
Has the appropriate paper type
been selected?
Select a proper mode.
8
Is the setting temperature of the
fuser roller in each paper type nor-
mal?
Check the setting and correct it. 08-
412,413,437,438
9
Using the recommended paper?
Use the recommended paper.
Developer material
10
Using the specified developer mate-
rial?
Use the specified developer material and
toner.
Scanner
11
Are the original glass (especially the
position of shading correction plate),
mirror and lens dirty?
Clean them.
Feeding direction
Approx.124mm