© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3 - 111
3
3.16 Adjustment of Dogleg
Dogleg is the name given to an image which is deformed approx. 44 mm of the trailing edge of the out-
put paper.
Since adjustment has usually been performed when the equipment was manufactured, dogleg image
should not occur. However, if the following dogleg image A or B does happen to occur, the following
adjustment must be performed. An original with a line parallel to the feeding direction is used for the
adjustment.
Fig. 3-153
Fig. 3-154
Fig. 3-155
Normal Image
Feeding
Direction
Feeding
Direction
Dogleg Image A
Approx. 44 mm of
the trailing edge
Dogleg Image B
Feeding
Direction
Approx. 44 mm of
the trailing edge
04/10