Testing the EZ Turn Switch (continued)
g202944
Figure 107
5. The EZ turn switch terminals are marked as shown in
. The
circuitry of the switch is shown in the
Circuit Logic Table (page 5–57)
. With
the use of a multimeter (ohms setting), test the switch functions to determine
if continuity exists between the various terminals for each switch position.
Check the continuity between the switch terminals.
Circuit Logic Table
Switch Position
Normal Circuits
Other Circuits
O
FF
1+2
4+5
O
N
2+3
5+6
6. Replace the EZ turn switch if necessary.
7. Connect the switch to the machine wire harness. Secure the console cover
to the handle.
8. Connect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 5–7)
.