Traction Switch
g202427
Figure 85
1.
Traction switch
3.
Bolt head
2.
Switch mount bracket
4.
Engagement lever
The traction switch is a normally open proximity switch. The switch is attached to
the handle assembly switch mount bracket (
When the traction engagement lever is not engaged, the head of the bolt in the
traction lever is positioned away from the target end of the traction switch so
that the switch is in its normal open state. The head of the bolt in the traction
engagement lever is moved toward the switch target when the traction lever is
engaged causing the switch to close.
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 5–35
Electrical System: Adjustments
12189SL Rev E