Servicing the Grooming Brush (Optional)
g229842
Figure 226
1.
Brush element
3.
Brush shaft
5.
Locknut (2 each)
2.
Roll pin (2 each)
4.
J-bolt (2 each)
6.
Spiral brush
The optional grooming brush attaches to the groomer in place of the groomer
reel. The grooming brush is removed and installed from the groomer in the same
manner as the groomer reel; refer to
Groomer Reel (page 9–12)
.
The grooming brush element or shaft can be serviced separately (
).
To remove the spiral grooming brush from the shaft, remove the locknut and
J-bolt from both ends of the brush assembly and slide the brush from the shaft.
When assembling the spiral brush to the shaft, ensure that the J-bolts are
installed with the threaded portion on the outside of the brush and tighten the
locknuts to
2.3 to 2.8 N∙m (20 to 25 in-lb)
.
Universal Groomer (Optional): Service and Repairs
Page 9–18
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E