Testing the Main Contactor (continued)
A. Locate the wire harness connector for work lights located on the left side
of the upper handle. The connector will be identified with a tag and will
have a pink and a black wire attached to the connector.
B. Remove the plug or work light harness connector (if the machine is
equipped with optional work lights) from the machine wire harness work
light connector.
C. The machine wire harness work light connector leading to the harness
black wire will be used for contactor voltage testing.
g204729
Figure 115
1.
Main contactor
3.
Main contact post
2.
Rubber boot
4.
Coil post
6. Use a multimeter to measure the voltage across the main contactor posts as
follows:
A. Position the rubber boots away from the main contactor posts to get
access to the posts with multimeter probes (
).
B. Connect the multimeter common (-) test probe to the ground connector in
the work light connector (step
).
C. Ensure that the traction lever is in the N
EUTRAL
position. Temporarily
connect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 5–7)
.
D. Turn the key switch to the S
TART
position to wake up the machine and
then turn the key switch to the R
UN
position. The main contactor should
click as it is energized.
E. Use the second multimeter test probe, check that all 4 posts on the main
contactor have system voltage (42 V to 64 V @ 100% state of charge)
present (
). If 1 or more posts do not have system voltage
present, the contactor is damaged. If none of the posts have voltage
present, ensure that common (-) test probe is still connected to the work
light connector and if so, look for electrical issues at other machine
components as the contactor is not being energized correctly.
F. Turn the key switch to the O
FF
position. The main contactor should click
as it is de-energized.
G. Disconnect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 5–7)
.
Electrical System: Testing the Electrical Components
Page 5–64
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E
Содержание Greensmaster eFlex 1800
Страница 4: ...NOTES NOTES Page 4 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 16: ...Safety Safety and Instructional Decals Page 1 8 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 120: ...g202945 Figure 72 Electrical System InfoCenter Display Page 5 20 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 280: ...Belt Driven Groomer Service and Repairs Page 8 32 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 312: ......