Angle Indicator and Magnetic Mount
Angle Indicator: Toro Part No. 131–6828
Magnetic Mount: Toro Part No. 131–6829
Because the top grind angle on bedknives is critical for edge
retention, and therefore after− cut appearance, Toro has
develop these service tools for accurately measuring the top
grind angle on all bedknives.
Since there can be variations in the mounting surface of the
bedbar, it is necessary to grind the bedknife after installing
it to the bedbar.
1. Place the angle indicator on the bottom side of the
bedknife with the digital display facing you as shown.
2. Press the Alt Zero button on the angle indicator.
g223327
Figure 8
1.
Bedknife
3.
Bedbar
2.
Angle Indicator
3. Remove the angle indicator and place the magnetic mount
on the edge of the bedknife so the face of the magnet is flat
against the top angle of the bedknife.
4. Place the angle indicator on the mount with the digital
display facing you as shown. The angle displayed on the
indicator is the current bedknife top angle.
g223326
Figure 9
1.
Angle indicator surface
4.
Bedbar
2.
Magnetic mount
5.
Angle indicator
3.
Bedknife
Bedknife Screw Tool
Toro Part No. TOR510880
This screwdriver-type bit is made to fit Toro bedknife
attaching screws. Use this bit with a torque wrench to secure
the bedknife to the bedbar.
IMPORTANT
Important: To prevent damage to the
bedbar, DO NOT use an air or manual
impact wrench with this tool.
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 2–17
Specifications and Maintenance: Special Tools
12189SL Rev E
Содержание Greensmaster eFlex 1800
Страница 4: ...NOTES NOTES Page 4 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 16: ...Safety Safety and Instructional Decals Page 1 8 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 120: ...g202945 Figure 72 Electrical System InfoCenter Display Page 5 20 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 280: ...Belt Driven Groomer Service and Repairs Page 8 32 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 312: ......