Relay (For Models 04042, 04043, 04046 and 04049 fitted with 04069)
g270848
Figure 117
1.
Relay
3.
Bolt (2 each)
2.
Nut (2 each)
4.
Mount bracket
The relay used on the eFlex machine is 5 terminal 48 V relay and located below
the TEC controller inside the battery cover: refer to
Testing the Relay
1. Park the machine on a level surface and place the traction lever in the
N
EUTRAL
position. Turn the key switch to the O
FF
position and remove the
key from the key switch.
2. Disconnect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 5–7)
.
3. Remove the 8 bolts that secures the battery cover to the mount bracket; refer
to
. Remove the battery cover from the mount bracket.
4. Note the position of the connectors and wire harness on the relay for the
assembly purposes. Disconnect the machine wire harness connectors from
the relay. Remove the relay from the machine for ease of testing.
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 5–67
Electrical System: Testing the Electrical Components
12189SL Rev E
Содержание Greensmaster eFlex 1800