Faults Screen
g202792
Figure 78
1.
Left/right button
4.
Fault items
2.
Down button
5.
Fault menu
3.
Menu/back button
The faults screen (
) will list all the machine electrical faults that have
occurred since the faults were last cleared from the InfoCenter. The faults will be
identified by a number and when the fault occurred. The faults that might occur
on the eFlex machine are listed in the
Fault Table (page 5–26)
.
The InfoCenter fault log can be cleared by selecting the clear system faults
menu item. The cleared faults will be removed from the InfoCenter but will be
retained in the TEC memory.
If a fault occurs during machine use, there may be a change in machine
functionality due to the fault. Should there be machine operation issues due
to a fault, a first step to remedy the issue would be to move the traction lever
to the N
EUTRAL
position, turn the key switch to the O
FF
position, and allow all
the machine functions to stop. Then, attempt to restart the machine to see if
operation has returned to normal. Some faults will be reset during the restart
and will then allow normal function. If a fault continues to occur, further system
evaluation and possible component repair or replacement will be necessary.
To return to the main menu screen from the faults screen, press the menu/back
button (as indicated by the
at the bottom of the screen).
Fault Table
Fault Identification
Fault Description
#1
Internal TEC fault
#2
12 VDC supply fault
#3
5 VDC supply fault
#4
Lithium battery pack bus fault
#5
CAN-bus communication fault
#6
Motor over current fault*
#7
Motor over temperature fault
#8
Motor overspeed fault*
#9
Internal electric motor fault
Electrical System: InfoCenter Display
Page 5–26
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E
Содержание Greensmaster eFlex 1800
Страница 4: ...NOTES NOTES Page 4 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 16: ...Safety Safety and Instructional Decals Page 1 8 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 120: ...g202945 Figure 72 Electrical System InfoCenter Display Page 5 20 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 280: ...Belt Driven Groomer Service and Repairs Page 8 32 Greensmaster eFlex 1800 2100 and 2120 12189SL Rev E ...
Страница 312: ......