Removing the Grooming Reel (Counter Rotating Groomer Drive) (continued)
3. Remove the cutting unit from the machine and place cutting unit on a flat
work area.
4. Ensure that the handle on groomer cover is rotated toward front of machine
so that the groomer drive is engaged.
5. Remove groomer cover assembly (item 22 in
) and gasket from
machine; refer to
Groomer Cover (Counter Rotating Groomer Drive) (page
. Discard gasket.
g228291
Figure 193
1.
Extension spring
3.
47T idler gear
2.
43T idler gear
4.
Groomer drive gear
6. Carefully remove extension spring from anchor points on right drive plate
(
).
g228292
Figure 194
1.
Right drive plate assembly
3.
43T gear/bearing
2.
Flange nut
4.
47T gear/bearing
7. Remove the 2 idler gears (43T and 47T) from the right drive plate assembly
(
). The bearings are pressed into the gears.
8. Loosen 2 bolts (item 7 in
) that secure front roller shaft to groomer
arms.
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 8–15
Belt Driven Groomer: Service and Repairs
12189SL Rev E