6-6
6 SPECIAL MODE (Menu Mode)
5
Press the
{F1}
or
{F2}
key to select using
GRID FACTOR.
[Example:F2 : DON’T USE]
{F2}
6
Press the
{F1}
key.
{F1}
7
Collimate prism A, and press the
{F1}
(MEAS) key.
Horizontal distance (HD) between the instrument
and prism A will be shown.
Collimate A
{F1}
The prism position will be decided.
8
Collimate prism B and press the
{F1}
(MEAS) key.
Horizontal distance (HD) between the instrument
and prism B will be shown.
Collimate B
{F1}
The horizontal distance (dHD) and relative
elevation (dVD) between prism A and B.
9
To show slope distance (dSD), press
{
}
key.
{
}
10
To measure the distance between points A and C,
press the
{F3}
(HD). *1)
{F3}
11
Collimate point C (Prism C) and press the
{F1}
(MEAS) key.
Horizontal distance (HD) between the instrument
and prism C will be shown.
Collimate
prism C
{F1}
MLM
F1:MLM-1(A-B, A-C)
F2:MLM-2(A-B, B-C)
MLM-1(A-B, A-C)
<STEP-1>
HD: m
MEAS R.HT NEZ NP/P
MLM-1(A-B, A-C)
<STEP-1>
HD*[n] << m
MEAS R.HT NEZ NP/P
MLM-1(A-B, A-C)
<STEP-1>
HD* 123.456 m
MEAS R.HT NEZ NP/P
MLM-1(A-B, A-C)
<STEP-2>
HD: m
MEAS R.HT NEZ NP/P
MLM-1(A-B, A-C)
<STEP-2>
HD*[n] << m
MEAS R.HT NEZ NP/P
MLM-1(A-B, A-C)
<STEP-2>
HD* 345.678 m
MEAS R.HT NEZ NP/P
MLM-1(A-B, A-C)
dHD : 123.456 m
dVD : 12.345 m
––– ––– HD –––
MLM-1(A-B, A-C)
dSD : 124.072 m
HR : 12°34'40"
––– ––– HD –––
MLM-1(A-B, A-C)
<STEP-2>
HD: m
MEAS R.HT NEZ NP/P