172-65710M-04 (SC-F71 Parameters/Functions) 23 Dec 2021
327
Table 9-1 List of screen numbers
No.
Name
Mode
1
Input 1_Measured value (PV)
monitor
1)
Input 1_Set value (SV) monitor
2)
Monitor & SV
setting mode
2
Input 2_Measured value (PV)
monitor
Input 2_Set value (SV) monitor
3) 4)
3
Measured value (PV) of
differential temperature input
monitor
Set value (SV) of differential
temperature input (SV) monitor
2)
4
Input 1_Measured value (PV)
Input 2_Measured value (PV)
5
Remote setting input value
monitor
6
Input 1_Manipulated output
value monitor [heat-side]
7
Input 1_Manipulated output
value monitor [cool-side]
8
Input 2_Manipulated output
value monitor
9
Comprehensive event state
10 Memory area soak time monitor
11 Input 1_Soft start remaining time
12 Input 2_Soft start remaining time
13 Interlock release
14 Memory area transfer
15 RUN/STOP transfer
Operation
transfer mode
16 Input 1_Autotuning (AT)
17 Input 2_Autotuning (AT)
18 Input 1_Startup tuning (ST)
19 Input 2_Startup tuning (ST)
20 Input 1_Auto/Manual transfer
21 Input 2_Auto/Manual transfer
22
Remote/Local transfer
Cascade mode transfer
PV select transfer
2-loop control/Differential
temperature control transfer
23
Control area Local/External
transfer
24 Input 1_Set value (SV)
Parameter
setting mode:
Parameter
group No.00
(
Pn00
)
25 Input 2_Set value (SV)
26
Set value (SV) of differential
temperature input (SV)
27
Event 1 set value (EV1)
Parameter
setting mode:
Parameter
group No.40
(
Pn40
)
Event 1 set value (EV1) [high]
28 Event 1 set value (EV1') [low]
29
Event 2 set value (EV2)
Event 2 set value (EV2) [high]
30 Event 2 set value (EV2') [low]
31
Event 3 set value (EV3)
Event 3 set value (EV3) [high]
32 Event 3 set value (EV3') [low]
33
Event 4 set value (EV4)
Event 4 set value (EV4) [high]
34 Event 4 set value (EV4') [low]
1)
Measured value (PV) of the PV select under the Control with
PV select.
2)
Input 1_Manual manipulated output value when Input 1 is in
Manual mode.
3)
Input 1_Manual manipulated output value when the control is
Cascade control in the Manual mode.
4)
Input 2_Manual manipulated output value when the control is
2-loop control and when Input 2 is in Manual mode.
No
Name
Mode
35
Input 1_Proportional band [heat-
side]
Parameter
setting mode
Parameter
group No.51
(
Pn51
)
36 Input 1_Integral time [heat-side]
37 Input 1_Derivative time [heat-side]
38
Input 1_ON/OFF action
differential gap (upper)
39
Input 1_ON/OFF action
differential gap (lower)
40
Input 1_Control response
parameter
41 Input 1_Proactive intensity
42 Input 1_Manual reset
43 Input 1_FF amount
44
Input 1_Output limiter high
[heat-side]
45
Input 1_Output limiter low [heat-
side]
46 Input 1_Dead zone
47 Input 2_Proportional band
Parameter
setting mode
Parameter
group No.52
(
Pn52
)
48 Input 2_Integral time
49 Input 2_Derivative time
50
Input 2_ON/OFF action
differential gap (upper)
51
Input 2_ON/OFF action
differential gap (lower)
52
Input 2_Control response
parameter
53 Input 2_Proactive intensity
54 Input 2_Manual reset
55 Input 2_FF amount
56 Input 2_Output limiter high
57 Input 2_Output limiter low
58 Input 2_Dead zone
59
Input 1_Proportional band [cool-
side]
Parameter
setting mode
Parameter
group No.56
(
Pn56
)
60 Input 1_Integral time [cool-side]
61 Input 1_Derivative time [cool-side]
62 Input 1_Overlap/Deadband
63
Input 1_Output limiter high [cool-
side]
64
Input 1_Output limiter low [cool-
side]
65
Select Trigger type for Memory
area transfer
Parameter
setting mode
Parameter
group No.70
(
Pn70
)
66 Area soak time
67 Link area number
68 Input 1_Soft start time (up)
69 Input 1_Soft start time (down)
70
Input 1_Setting change rate
limiter (up)
71
Input 1_Setting change rate
limiter (down)
72
Input 1_Auto/Manual transfer
selection (Area transfer)
73
Input 1_Manipulated output
value (Area transfer)
74 Input 2_Soft start time (up)
75 Input 2_Soft start time (down)
76
Input 2_Setting change rate
limiter (up)
77
Input 2_Setting change rate
limiter (down)
78
Input 2_Auto/Manual transfer
selection (Area transfer)
79
Input 2_Manipulated output
value (Area transfer)
80
Remote/Local transfer selection
(Area transfer)
Содержание SC-F71
Страница 16: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 15 2 loop control Cascade control Control with PV select ...
Страница 17: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 16 ...
Страница 18: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 17 Differential temperature control ...
Страница 114: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 113 Setting procedure ...
Страница 131: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 130 Setting procedure ...
Страница 134: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 133 Setting procedure ...
Страница 141: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 140 Setting procedure ...
Страница 153: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 152 Setting procedure ...
Страница 158: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 157 Setting procedure ...
Страница 168: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 167 Setting procedure ...
Страница 172: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 171 Setting procedure ...
Страница 175: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 174 Setting procedure ...
Страница 180: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 179 Setting procedure ...
Страница 185: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 184 ...
Страница 199: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 198 Setting procedure ...
Страница 207: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 206 Setting procedure ...
Страница 236: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 235 Setting procedure Selecting Heating Cooling PID control ...
Страница 249: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 248 Setting procedure ...
Страница 280: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 279 Setting procedure ...
Страница 293: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 292 Checking PID values ...
Страница 303: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 302 Setting procedure ...
Страница 316: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 315 Setting procedure ...
Страница 320: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 319 Setting procedure ...
Страница 347: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 346 Operating procedure ...
Страница 359: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 358 Setting Procedure Setting Soft start function ...
Страница 388: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 387 Setting procedure ...