172-65710M-04 (SC-F71 Parameters/Functions) 23 Dec 2021
239
2: Heating/Cooling PID control with Autotuning [Cooling linear type]
3: Pressure control operation [MC-COS(R)-3]
4: Pressure control operation [MC-COS(R)-16, 15 to 50 mm]
5: Pressure control operation [MC-COS(R)-16, 65 to 150 mm]
6: Pressure control operation [MC-COS(R)-21]
7: Pressure control operation [MC-VCOS(R)]
8: Temperature control operation [MC-COS(R)-16]
9: Temperature control operation [MC-VCOS(R)]
For cascade control, only 0 or 1 are selectable.
For PV select, only 0, 1 or 2 are selectable.
time of order.
Refer to “4. Parameters that are Initialized/Modified when Setting is Changed” for
the parameters that are initialized when the Input 1_Control action is changed.
Input 1_Valve coefficient A to E [Engineering Mode: Function block No. 53
(
Fn53
)]
Parameter symbol
Data range
Factory set value
1. A
-1999 to 9999
0
1. b
-1999 to 9999
0
1. C
-1999 to 9999
0
1. d
-1999 to 9999
0
1. E
-1999 to 9999
0
Valve coefficient value (A to F) is indicated in the valve coefficient plate
(attached) on the MC-(V)COS(R), which is also indicated on the valve
coefficient tag when the equipment is new.
To display “Input 1_Valve coefficient A to E”, choose “3 to 7 (Pressure control
operation [MC-
(V)COS(R)])” or “8 and 9 (Temperature control operation [MC-
(V)COS(R)])” in Function block No. 51: Input 1_Control action (Engineering mode).
Input 1_Valve coefficient F [Engineering Mode: Function block No. 53 (
Fn53
)]
Parameter symbol
Data range
Factory set value
1. F
When Input 1_Control action is set to 3 to 6 or 8:
0: kg/cm
2
G
1: barg
2: psig
3: kPaG
4: MPaG
When Input 1_Control action is set to 7 or 9:
10: mmHg/Torr
11: mbar
12: inHg
13: psi
14: kPa
NOTE: To use a pressure unit other than the valve coefficient
F indicated on the valve coefficient plate, refer to the
"Converting valve coefficient" section in "8.8 Using with MC-
COS/MC-VCOS" in the instruction manual
(parameters/functions) to convert the valve coefficient and
change the valve coefficient F along with valve coefficients A,
C, and E.
Product identification code
specified at the time of
order.
Valve coefficient value (A to F) is indicated in the valve coefficient plate
(attached) on the MC-(V)COS(R), which is also indicated on the valve
coefficient tag when the equipment is new.
To display “Input 1_Valve coefficient F”, choose “3 to 7 (Pressure control
operation [MC-
(V)COS(R)])” or “8 and 9 (Temperature control operation [MC-
Содержание SC-F71
Страница 16: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 15 2 loop control Cascade control Control with PV select ...
Страница 17: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 16 ...
Страница 18: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 17 Differential temperature control ...
Страница 114: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 113 Setting procedure ...
Страница 131: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 130 Setting procedure ...
Страница 134: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 133 Setting procedure ...
Страница 141: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 140 Setting procedure ...
Страница 153: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 152 Setting procedure ...
Страница 158: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 157 Setting procedure ...
Страница 168: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 167 Setting procedure ...
Страница 172: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 171 Setting procedure ...
Страница 175: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 174 Setting procedure ...
Страница 180: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 179 Setting procedure ...
Страница 185: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 184 ...
Страница 199: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 198 Setting procedure ...
Страница 207: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 206 Setting procedure ...
Страница 236: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 235 Setting procedure Selecting Heating Cooling PID control ...
Страница 249: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 248 Setting procedure ...
Страница 280: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 279 Setting procedure ...
Страница 293: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 292 Checking PID values ...
Страница 303: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 302 Setting procedure ...
Страница 316: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 315 Setting procedure ...
Страница 320: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 319 Setting procedure ...
Страница 347: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 346 Operating procedure ...
Страница 359: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 358 Setting Procedure Setting Soft start function ...
Страница 388: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 387 Setting procedure ...