Refrigeration Maintenance
10-10
REFRIGERANT LEAKS
Use soap bubbles or a Halogen leak detector with a minimal sensitivity of 5g/year(e.g. electronic detector) to leak test the
refrigeration system. Inspect for signs of oil leakage, which is the first sign of a leak in the refrigeration system.
NOTE: It is normal for compressor shaft seals to have a slightly oily film.
EVACUATING AND CHARGING SMART REEFER MULTI-TEMP SYSTEMS
Set-up Unit
The Multi-Temp microprocessor must be placed in the Evacuation Test to evacuate and charge the unit. When the microprocessor
is in the Evacuation Test it opens all the normally closed solenoid valves in the refrigeration system. This allows the refrigeration
system to be evacuated properly. Refer to the appropriate Diagnostic Manual for complete information about the microprocessor.
SYSTEM EVACUATION
NOTE: Use the Service Test mode to operate units with a TG-VI, µP-IV, µP-V, µP-VI, SR-2 or SR-3 controller. See the
appropriate Controller Operation and Diagnosis manual for instructions.
Evacuation is Important and Critical to System Performance
Testing and system analysis shows that refrigeration systems, which contain non-condensables such as nitrogen and/or air, can
be overcharged with refrigerant when charged using the sight glass method. An overcharge of refrigerant will cause compressor
damage.
Therefore, Thermo King recommends that all major repairs to the refrigeration system include the removal and reclamation
(cleaning) of the refrigerant, followed by a thorough evacuation using the proper tools and procedures. A major repair is any
repair that requires soldering, replacement of a major system component or leaves open a portion of the system to the atmosphere
for more than 30 minutes.
Содержание SLXi Spectrum
Страница 17: ...Safety Precautions 2 5 Warning Decals...
Страница 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Страница 74: ...Unit Description 5 30...
Страница 128: ...Controller Operation 7 28...
Страница 156: ...Electrical Maintenance 8 28...
Страница 177: ...Engine Maintenance 9 21 Integral Fuel Solenoid Components 1 Integral Fuel Solenoid 2 O ring 3 Fuel Injection Pump Groove...
Страница 234: ...Refrigeration Maintenance 10 22...
Страница 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Страница 316: ...Mechanical Diagnosis 13 8...
Страница 322: ...Refrigeration System Diagnosis 14 6...
Страница 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Страница 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Страница 340: ...Multi Temperature Refrigeration System Diagrams 16 8...
Страница 342: ...Wiring Diagrams and Wiring Schematics 17 2...