Structural Maintenance
12-17
4. Attach the damper door bracket to the damper door. Snug the mounting screws enough to hold the damper door bracket in
place, but do not completely tighten the mounting screws.
5. Position the damper door bracket so the mounting screws are in the middle of the slots in the damper door.
6. Attach the other end of the ball joint link to the damper link with a stainless steel screw, lock washer, and two flat washers.
The flat washers should be placed between the ball joint link and the damper link. Check to make sure that the ball joint link
is approximately vertical (see “Align Ball Joint Vertically” illustration). Add or remove flat washers between the ball joint
link and the damper link to align the ball joint link vertically. The ball joint link must be aligned vertically or it may bind and
interfere with the operation of the damper system.
Align Ball Joint Vertically – SL
1. Damper Door Bracket
2. Ball Joint Link
3. Damper Link
4. Flat Washers
Содержание SLXi Spectrum
Страница 17: ...Safety Precautions 2 5 Warning Decals...
Страница 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Страница 74: ...Unit Description 5 30...
Страница 128: ...Controller Operation 7 28...
Страница 156: ...Electrical Maintenance 8 28...
Страница 177: ...Engine Maintenance 9 21 Integral Fuel Solenoid Components 1 Integral Fuel Solenoid 2 O ring 3 Fuel Injection Pump Groove...
Страница 234: ...Refrigeration Maintenance 10 22...
Страница 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Страница 316: ...Mechanical Diagnosis 13 8...
Страница 322: ...Refrigeration System Diagnosis 14 6...
Страница 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Страница 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Страница 340: ...Multi Temperature Refrigeration System Diagrams 16 8...
Страница 342: ...Wiring Diagrams and Wiring Schematics 17 2...