Controller Operation
7-15
Selecting Economy Mode - Revision 4000 and 4010 Software Only
NOTE: Economy Mode is controlled using OptiSet and this display does not appear in Revision 4020, 4021, and later software.
The Economy mode can be turned ON or OFF for both CYCLE-SENTRY and Continuous Run operation.
Economy mode extends the length of the Null mode on CYCLE-SENTRY operation. The CYCLE-SENTRY Null Range changes
from 2.8 C to 5.6 C (default setting) when the Economy mode is ON. The CYCLE-SENTRY Null Range can also be adjusted
from 2.8 C to 11.2 C.
The Economy mode extends the Low Speed Cool mode on Continuous Run operation. The Low Speed Switch Point changes
from 2.0 C to 5.6 C (default setting) when the Economy mode is ON. The Low Speed Switch Point can also be adjusted from
1.7 C to 8.4 C.
1. With the Standard Display on the controller, press and release the MODE key until ECOn appears in the upper display.
2. Press the UP or DOWN arrow key until the desired setting shows in the lower display.
• Yes = CYCLE-SENTRY mode
• No = Continuous Run mode
NOTE: If OptiSet has been programmed to determine the Economy mode setting, the arrow keys will not change the screen
setting.
3. When the correct setting shows in the lower display, press the ENTER key to load the new setting in the controller memory.
• “LOAD” will appear in the lower display for a few seconds.
• CYCLE-SENTRY icon appears in the display when CYCLE-SENTRY mode is selected.
• If the ENTER key is not pressed, the operating mode will NOT change and the display will return to the standard display
in about 10 seconds.
Viewing Information (Display) Screens
General unit operating information including mode settings, sensor temperatures and hourmeters can be easily viewed.
NOTE: Each screen will show for 10 seconds if no other key is pressed. These screens can be locked on the display by pressing
the ENTER key within 10 seconds. Press any key to unlock the display.
µP-VI Keypad
1.
MODE Key
2.
HOURS Key
3.
GAUGES Key
4.
PRETRIP Key
5.
TK Key
6.
SELECT Key
7.
UP Key
8.
DOWN Key
9.
ENTER Key
10. ALARM Key
11. ALARM CLEAR Key
HOURS
SELECT
SETPOINT
ENTER
CODE
CLEAR
ALARM
!
C
▲ ▲
▲
GAUGES
MODE
PRETRIP
P
HOURS
1
2
3
4
5
6
7
8
9
10
11
Содержание SLXi Spectrum
Страница 17: ...Safety Precautions 2 5 Warning Decals...
Страница 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Страница 74: ...Unit Description 5 30...
Страница 128: ...Controller Operation 7 28...
Страница 156: ...Electrical Maintenance 8 28...
Страница 177: ...Engine Maintenance 9 21 Integral Fuel Solenoid Components 1 Integral Fuel Solenoid 2 O ring 3 Fuel Injection Pump Groove...
Страница 234: ...Refrigeration Maintenance 10 22...
Страница 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Страница 316: ...Mechanical Diagnosis 13 8...
Страница 322: ...Refrigeration System Diagnosis 14 6...
Страница 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Страница 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Страница 340: ...Multi Temperature Refrigeration System Diagrams 16 8...
Страница 342: ...Wiring Diagrams and Wiring Schematics 17 2...