Safety Precautions
2-4
Precautions
1. Be certain the unit On/Off switch is turned OFF before connecting or disconnecting the standby power plug. Never attempt
to stop the unit by disconnecting the power plug.
2. Be certain the unit power plug is clean and dry before connecting it to a power source.
3. When working on high voltage circuits on the temperature control unit, do not make any rapid moves. If a tool drops, do not
grab for it. People do not contact high voltage wires on purpose. It occurs from an unplanned movement.
4. Use tools with insulated handles that are in good condition. Never hold metal tools in your hand if exposed, energised
conductors are within reach.
5. Treat all wires and connections as high voltage until a meter and wiring diagram show otherwise.
6. Never work alone on high voltage circuits on the temperature control unit. Another person should always be present to shut
off the temperature control unit and provide aid in the event of an accident.
7. Have electrically insulated gloves, cable cutters and safety glasses available in the immediate vicinity in the event of an
accident.
Warning:
Care must be taken because all external panels are heavier on the SLX, SLXe and SLXi Whisper than on standard
SLX, SLXe and SLXi Units.
First Aid
IMMEDIATE action must be initiated after a person has received an electrical shock. Obtain immediate medical assistance if
available.
The source of shock must be immediately removed by either shutting down the power or removing the victim from the source.
If it is not possible to shut off the power, the wire should be cut with either an insulated instrument (e.g., a wooden handled axe
or cable cutters with heavy insulated handles) or by a rescuer wearing electrically insulated gloves and safety glasses. Whichever
method is used, do not look at the wire while it is being cut. The ensuing flash can cause burns and blindness.
If the victim has to be removed from a live circuit, pull the victim off with a non-conductive material. Use the victim’s coat,
a rope, wood, or loop your belt around the victim’s leg or arm and pull the victim off. DO NOT TOUCH the victim. You can
receive a shock from current flowing through the victim’s body. After separating the victim from power source, check
immediately for the presence of a pulse and respiration. If a pulse is not present, start cardiopulmonary resuscitation and call for
emergency medical assistance. If a pulse is present, respiration may be restored by using mouth-to-mouth resuscitation, but call
for emergency medical assistance.
UNIT DECALS
Serial number decals, refrigerant type decals and warning decals appear on all Thermo King equipment. These decals provide
information that may be needed to service or repair the unit. Service technicians should especially read and follow the instructions
on all warning decals.
Refrigerant Decals
Содержание SLXi Spectrum
Страница 17: ...Safety Precautions 2 5 Warning Decals...
Страница 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Страница 74: ...Unit Description 5 30...
Страница 128: ...Controller Operation 7 28...
Страница 156: ...Electrical Maintenance 8 28...
Страница 177: ...Engine Maintenance 9 21 Integral Fuel Solenoid Components 1 Integral Fuel Solenoid 2 O ring 3 Fuel Injection Pump Groove...
Страница 234: ...Refrigeration Maintenance 10 22...
Страница 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Страница 316: ...Mechanical Diagnosis 13 8...
Страница 322: ...Refrigeration System Diagnosis 14 6...
Страница 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Страница 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Страница 340: ...Multi Temperature Refrigeration System Diagrams 16 8...
Страница 342: ...Wiring Diagrams and Wiring Schematics 17 2...