Electrical Maintenance
8-5
NOTE: An alternator can easily exceed its rated output. An alternator MUST at least reach its rated output when full fielded.
An alternator that has a defective rectifier diode may reach 75% of its rated output with a full field.
13. Stop the unit.
14. Use the readings obtained previously to determine the problem by referring to the Diagnosis Chart.
NOTE: This assumes that the alternator did not charge properly prior to the full field test.
Field Current Test
(Checks the field windings, brushes and slip rings)
Perform this test with the On-Off switch in the OFF position.
1. Attach a clamp-on ammeter to the 2A wire near the B+ terminal on the alternator.
2. Connect a jumper wire between the F2 terminal on the alternator and a chassis ground, and note the ammeter reading.
3. The ammeter reading indicates field current. The following chart shows the field current for each alternator with 12 volts
applied to the field:
a. No field current or a low field current indicates an open circuit or excessive resistance in the field circuit. Replace the
voltage regulator and brush assembly, inspect the slip rings and repeat the test. If the brushes are not the problem, replace
the rotor or the alternator.
b.High field current indicates a short in the field circuit. Repair or replace the alternator.
Alternator Rating
Field Current 12 Volts
23 Amp
37 Amp
65 Amp
120 Amp
1.0 to 3.0 Amps
3.5 to 4.5 Amps
4.0 to 5.0 Amps
5.0 to 6.0 Amps
Removing Screws and Bolts
1.
Through Bolts
2.
Screws surrounding rotor shaft
Содержание SLXi Spectrum
Страница 17: ...Safety Precautions 2 5 Warning Decals...
Страница 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Страница 74: ...Unit Description 5 30...
Страница 128: ...Controller Operation 7 28...
Страница 156: ...Electrical Maintenance 8 28...
Страница 177: ...Engine Maintenance 9 21 Integral Fuel Solenoid Components 1 Integral Fuel Solenoid 2 O ring 3 Fuel Injection Pump Groove...
Страница 234: ...Refrigeration Maintenance 10 22...
Страница 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Страница 316: ...Mechanical Diagnosis 13 8...
Страница 322: ...Refrigeration System Diagnosis 14 6...
Страница 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Страница 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Страница 340: ...Multi Temperature Refrigeration System Diagrams 16 8...
Страница 342: ...Wiring Diagrams and Wiring Schematics 17 2...