Controller Operation
7-7
THERMOGUARD TG-VI CONTROLLER
The Thermoguard TG-VI controller is a one-piece, programmable microprocessor. The microprocessor uses external relays to
control unit functions to maintain the cargo at the proper temperature. The TG-VI continuously monitors unit operational
information including: Return air, discharge air and coil temperature sensors; unit hourmeters; oil pressure gauge; water
temperature gauge; voltmeter; tachometer; mode indicators; and temperature control system controls.
Several different TG-VI microprocessor controller options are available. To determine the TG-VI controller options available
on your unit, check the label at the top of the controller.
•
THERMOGUARD VI:
This label means that the controller includes the CYCLE-SENTRY option, but DOES NOT include
the Modulation option.
•
THERMOGUARD VIa:
This label means that the controller DOES NOT include the CYCLE-SENTRY option or the
Modulation option (no options).
•
THERMOGUARD VIb:
This label means that the controller includes BOTH the CYCLE-SENTRY option and the
Modulation option.
WARNING: Units equipped with THERMOGUARD VI and THERMOGUARD VIb controllers may START automatically
AT ANY TIME when the On/Off switch is in the ON position and the CYCLE-SENTRY icon APPEARS in the TG-VI display
(CYCLS screen in menu display set to YES). Make sure to turn the On/Off switch OFF before opening unit doors or inspecting
or working on any part of the unit.
CAUTION: The Unit On/Off switch MUST be in the OFF position before disconnecting or connecting the unit battery.
NOTE: Refer to the appropriate Controller Operation and Diagnosis Manual for complete operation and diagnosis
information.
Unit operational information appears on liquid crystal display (LCD). During normal operation, the Standard Display appears on
the screen. The Standard Display shows the return air temperature (upper display) and the setpoint temperature (lower display).
A keypad allows the operator to select information to display and programme unit features including the setpoint temperature. If
no key is pressed for about 10 seconds, the display will return to the Standard Display. Check the symbols (icons) that appear on
the display. These symbols identify the operating information that currently appears.
TG-VI Display Screen
1.
Temperature Display (Upper Display)
2.
Cool Symbol
3.
Heat Symbol
4.
Defrost Symbol
5.
Setpoint Display (Lower Display)
6.
Setpoint Symbol
7.
Electric Standby Symbol
8.
Alarm Symbol
9.
Cycle-Sentry Symbol
1
2
3
4
9
8
7
5
6
Содержание SLXi Spectrum
Страница 17: ...Safety Precautions 2 5 Warning Decals...
Страница 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Страница 74: ...Unit Description 5 30...
Страница 128: ...Controller Operation 7 28...
Страница 156: ...Electrical Maintenance 8 28...
Страница 177: ...Engine Maintenance 9 21 Integral Fuel Solenoid Components 1 Integral Fuel Solenoid 2 O ring 3 Fuel Injection Pump Groove...
Страница 234: ...Refrigeration Maintenance 10 22...
Страница 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Страница 316: ...Mechanical Diagnosis 13 8...
Страница 322: ...Refrigeration System Diagnosis 14 6...
Страница 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Страница 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Страница 340: ...Multi Temperature Refrigeration System Diagrams 16 8...
Страница 342: ...Wiring Diagrams and Wiring Schematics 17 2...