Operating Instructions
6-5
• CYCLE-SENTRY (Auto Start-Stop): All unit starting functions including glow plug (or air heater) preheat, fuel and throttle
solenoid control, and cranking are performed automatically.
NOTE: Units equipped with a µP-VI controller include the CYCLE-SENTRY mode as standard in the software menu display.
Scroll to the CYCLS screen in the menu display. Then press ARROWS key to select CYCLS YES (CYCLE-SENTRY
operation) or CYCLS NO (Continuous Run operation). Then press the ENTER key to load desired operating mode. The
display will briefly show “LOAD” or “Lod”. The CYCLE-SENTRY icon will appear in the controller display when
CYCLE-SENTRY operation is selected.
NOTE: Units with a MT µP-IV (Except Multi-Temp MT µP-IV), µP-V, µP-VI controller include a CYCLE-SENTRY
Fresh (CSFR) feature. If CSFR is active and the setpoint is within the programmed lockout range, the CYCLE-SENTRY
symbol will flash while the unit is automatically starting. After the unit starts, the CYCLE-SENTRY symbol will disappear
and the unit will operate in Continuous Run.
The engine starts automatically whenever the controller calls for cooling or heating; the engine block temperature decreases to
-1 C; the manual defrost switch, air switch or defrost timer initiates defrost; or the battery voltage drops below the
CYCLE-SENTRY setting (TG-VI, MT µP-IV, µP-V, µP-VI controllers only).
The engine operates until the controller reaches setpoint; the block temperature reaches 32 C; and the battery is sufficiently
charged.
Electric Operation:
• CONTINUOUS RUN. Modulation Cool (option) is activated at setpoints above -5 C (-9 C or -4 C on some units). The unit
operates on Cool, Modulation Cool and Null.
• CYCLE-SENTRY (Auto Start-Stop) (CYCLE-SENTRY icon appears in TG-VI, Multi-Temp MT µP-IV, µP-V or µP-VI
controller). Modulation (option) is disabled unless the CYCLE-SENTRY Fresh (CSFR) feature is active and the setpoint
is within the programmed lockout range. The unit operates on Cool and Null (except when CSFR is active).
CONTROLLER
Set the controller at the required temperature. Adjusting the setpoint lower than required will not make the unit cool faster.
The TG-VI controller is a solid-state, programmable microprocessor that controls all unit functions to maintain the cargo at the
proper temperature. A keypad controls the operation of the microprocessor while operating information appears on a liquid
crystal display (LCD). The TG-VI integrates the following functions: temperature sensors, hourmeters, oil pressure gauge, water
temperature gauge, voltmeter, tachometer, operating mode indicator, and refrigeration system controls.
The MT µP-IV, Multi-Temp MT µP-IV, µP-V and µP-VI controllers are solid-state, programmable microprocessors that control
all unit functions to maintain the cargo at the proper temperature. The Multi-Temp MT µP-IV also controls each remote
evaporator. A keypad controls the operation of the microprocessor while operating information appears on a liquid crystal display
(LCD). The controllers integrate the following functions: temperature sensors, hourmeters, oil pressure gauge, water temperature
gauge, ammeter, voltmeter, tachometer, operating mode indicator, refrigeration system thermostat, diagnostic system, data logger
(optional) and Tracker (optional).
The SR-2/SR-3 controller is a programmable microprocessor that controls all unit functions to maintain the cargo at the proper
temperature. The SR-2/SR-3 integrates the following functions: changing setpoint and operating mode, viewing gauge/sensor and
hourmeter readings, initiating Defrost cycles, viewing and clearing alarms.
Smart Reefer Controller Single Temperature
(example SR-2 shown)
1.
On Key (Dedicated Key)
2.
Off Key (Dedicated Key)
3.
Display
4.
Defrost Key (Dedicated Key)
5.
Mode Key (Dedicated Key)
6.
Soft Keys
1
2
4
5
3
6
Содержание SLXi Spectrum
Страница 17: ...Safety Precautions 2 5 Warning Decals...
Страница 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Страница 74: ...Unit Description 5 30...
Страница 128: ...Controller Operation 7 28...
Страница 156: ...Electrical Maintenance 8 28...
Страница 177: ...Engine Maintenance 9 21 Integral Fuel Solenoid Components 1 Integral Fuel Solenoid 2 O ring 3 Fuel Injection Pump Groove...
Страница 234: ...Refrigeration Maintenance 10 22...
Страница 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Страница 316: ...Mechanical Diagnosis 13 8...
Страница 322: ...Refrigeration System Diagnosis 14 6...
Страница 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Страница 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Страница 340: ...Multi Temperature Refrigeration System Diagrams 16 8...
Страница 342: ...Wiring Diagrams and Wiring Schematics 17 2...